Owner manual

610.44520.40.000 46 / 52 © Gardner Denver Deutschland GmbH
Servicing
Keypad
(PC)
1)
Malfunction Cause Remedy Carried
out by
Mains voltage too low Check mains voltage
DCbus voltage too low Check supply module
LU

DCbus
undervoltage
400 V frequency inverter
connected to 230 V mains
Connect frequency inverter to the
correct mains voltage.
Electrician
Shortcircuit Search for cause of shortcircuit;
check motor cable.
Operator
Electrician
OC1

(11)
Shortcircuit
Excessive capacitive charging
current of the motor cable
Use shorter motor cable with
lower charging current..
Electrician
Grounded motor phase Check motor, check motor cable OC2

(12)
Earth fault
Excessive capacitive charging
current of the motor cable
Use shorter motor cable with
lower charging current.
Electrician
Acceleration time too short
(C0012)
Increase acceleration time
Check drive dimensioning
U
min
- boost (C0016) set too
large or too small
Correct setting
Only for operation with
control cabinet inverter
2FCxxxx2NE00
U/f- rated frequency (C0015)
set too small
Correct setting
Differential pressure too high Check differential pressure of the
system.
Side channel blower starts at
half throttle
Increase acceleration time
Open valves.
Operator
Frequency
inverter overload
during
acceleration
Impeller jammed Repair side channel blower. Service
*)
Defective motor cable Check wiring.
OC3

(13)
Shortcircuit
Interturn fault in the motor Check motor.
Electrician
Deceleration time too short
(C0013)
OC4

(14)
Frequency
inverter overload
during
deceleration
Energy backflow in generator
mode operation too high
Increase deceleration time. Operator
OC5

(15)
Frequency
inverter overload
in stationary
operation
Frequent and too long overload Check dimensioning of side
channel blower.
Operator
OC6

(16)
Motor overload
(I
2
x t - overload)
Motor is thermally overloaded,
for instance, because of
impermissible continuous
current
frequent or too long
acceleration processes
Check dimensioning of side
channel blower.
Operator
OH

(50)
Heatsink
temperature> +85
°C
Ambient temperature too high Allow frequency inverter to cool
down and ensure better
ventilation.
Operator
Heatsink strongly polluted Clean heatsink
Check dimensioning of side
channel blower..
Operator
OH

Heatsink
temperature> +80
°C
Impermissibly high currents or
frequent and too long
accelerations
Check load, if necessary,
replace defective bearings
Service
*)