Commissioning
The base settings are now completed and the drive can be started:
Start drive Note
Enter the setpoint.
A) Using the keypad Set desired output frequency
under C0140.
The min. frequency under
C0010 and the setpoint offset
under C0140 are added!
B) Using the potentiometer via terminals 7, 8,
9
Terminal E3 E4
34 Hz (2000/min) HIGH LOW
67 Hz (4000/min) LOW HIGH
12.
C) Enter fixed speed via terminal.
50 Hz (3000/min) HIGH HIGH
13. Enable controller.
misc00
2
Terminal X3/28 = HIGH
14. The drive now operates with the set
frequency. The current output frequency is
indicated under C0050.
Set Disp
SubCod e Para
H / L
If the drive does not start, press
in addition.
5.4 Shut-down of the pump-motor unit
Shut-down:
1 Set controller inhibit (terminal X3/28 = LOW)
2 Switch off power supply.
3 Close shut-off device in inlet/ pressure line.