Owner manual

610.44520.40.000 38 / 52 © Gardner Denver Deutschland GmbH
Commissioning
Code Possible settings IMPORTANT
No. Designation Manu-
facturer
Selection
C0010 Minimum output
frequency
10,00 0,00 {0,02 Hz} 650,00 C0010 only limits the analog input 1
Only valid for units 2BH...N.1.
and 2BH...N.3.with integrated
2FCxxxx1NE00 inverter
C0011 Maximum output
frequency
86,00 7,50 {0,02 Hz} 650,00
Maximum permissible value: 86
(5000/min)
Only valid for units 2BH...N.1.
and 2BH...N.3.with integrated
2FCxxxx1NE00 inverter
10,00 Setting for units up to 5.5 kW
25,00
Setting for 7.5 kW unit
C0012 Acceleration time
main setpoint
0,00 {0,02 s} 1300,00 Reference: frequency change 0 Hz ...
C0011
Only valid for units 2BH...N.1.
and 2BH...N.3.with integrated
2FCxxxx1NE00 inverter
10,00 Setting for units up to 5.5 kW
20,00
Setting for 7.5 kW unit
C0013 Deceleration time
main setpoint
0,00 {0,02 s} 1300,00 Reference: frequency change 0 Hz ...
C0011
Only valid for units 2BH...N.1.
and 2BH...N.3.with integrated
2FCxxxx1NE00 inverter
52,70 Setting for units 2BH...N.3.
90,90
Setting for units 2BH...N.1.
C0015 U/frated
frequency
7,50 {0,02 Hz} 960,00
][*
][
][
][0015 Hzf
VU
VU
HzC
r
r
N
U
N
= mains rated voltage of
inverter
U
r
= rated voltage of motor
depending on connection method
acc. to rating plate
f
r
= rated frequency of motor acc.
To rating plate
The setting applies to the entire
mains voltage range in which the
inverter may be operated.
C0016 U
min
boost (starting
voltage
0,00 {0,01 %} 40,00 Depends on the device
Loadindependent rise of motor
voltage at low speeds:
Reference: rated voltage of motor
(C0090).
The setting applies to the entire
mains voltage range in which the
inverter may be operated.