Commissioning
Code Possible settings IMPORTANT
No. Designation Manu-
facturer
Selection
C0010 Minimum output
frequency
10,00 0,00 {0,02 Hz} 650,00 C0010 only limits the analog input 1
Only valid for units 2BH.−..N.1−.
and 2BH.−..N.3−.with integrated
2FCxxxx−1NE00 inverter
C0011 Maximum output
frequency
86,00 7,50 {0,02 Hz} 650,00
Maximum permissible value: 86
(5000/min)
Only valid for units 2BH.−..N.1−.
and 2BH.−..N.3−.with integrated
2FCxxxx−1NE00 inverter
10,00 Setting for units up to 5.5 kW
25,00
Setting for 7.5 kW unit
C0012 Acceleration time
main setpoint
0,00 {0,02 s} 1300,00 Reference: frequency change 0 Hz ...
C0011
Only valid for units 2BH.−..N.1−.
and 2BH.−..N.3−.with integrated
2FCxxxx−1NE00 inverter
10,00 Setting for units up to 5.5 kW
20,00
Setting for 7.5 kW unit
C0013 Deceleration time
main setpoint
0,00 {0,02 s} 1300,00 Reference: frequency change 0 Hz ...
C0011
Only valid for units 2BH.−..N.1−.
and 2BH.−..N.3−.with integrated
2FCxxxx−1NE00 inverter
52,70 Setting for units 2BH.−..N.3−.
90,90
Setting for units 2BH.−..N.1−.
C0015 U/f−rated
frequency
7,50 {0,02 Hz} 960,00
][*
][
][
][0015 Hzf
VU
VU
HzC
r
r
N
U
N
= mains rated voltage of
inverter
U
r
= rated voltage of motor
depending on connection method
acc. to rating plate
f
r
= rated frequency of motor acc.
To rating plate
The setting applies to the entire
mains voltage range in which the
inverter may be operated.
C0016 U
min
boost (starting
voltage
0,00 {0,01 %} 40,00 Depends on the device
Load−independent rise of motor
voltage at low speeds:
Reference: rated voltage of motor
(C0090).
The setting applies to the entire
mains voltage range in which the
inverter may be operated.