Owner manual

610.44520.40.000 20 / 52 © Gardner Denver Deutschland GmbH
Installation
1 Select suitable mounting elements.
2 Position the pumpmotor unit as close to the
wall as possible on a stable supporting plate
with sufficient loadbearing capacity.
The pumpmotor unit must be positioned
with the base towards the wall.
3 Attach the pumpmotor unit to the wall:
Screw the base of the pumpmotor unit to
the wall via the mounting holes.
When doing so, be sure to provide all
mounting holes with screws!
4 Remove the supporting plate.
4.1.4 Final works
After installing the pumpmotor unit, the eye bolt
must be removed or screwed tightly.
4.2 Mounting of the muffler
The pumpmotor units are supplied with mufflers
for inlet and discharge connections as standard.
The mufflers are marked by arrows in the
following drawings.
2BH721 ...2BH761 (singleimpeller pumpmotor
units)
ne2bhxn003a
Fig. 7: Mounting of the muffler 2BH721 ...2BH761.
With the following pumpmotor units, the
inletside muffler is included loose for
packagingrelated reasons. It must be mounted
by the operator.
2BH732 ... 2BH762 (twoimpeller pumpmotor
units with twostage design)
ne2bhxn003b
Fig. 8: Mounting of the muffler 2BH732 ... 2BH762
2BH763 (threeimpeller pumpmotor unit with
threestage design)
ne2bhxn003c
Fig. 9: Mounting of the muffler 2BH763
WARNING
Danger from rotating impeller:
cutting/cutting off of extremities!
The rotating impeller is accessible with the inlet
and discharge connections open!
With free entry and exit of gases, i.e. with direct
intake out of the atmosphere or direct feeding
into the atmosphere without piping, the
following therefore applies:
Provide the inlet and discharge connections of
the pumpmotor unit either with additional
mufflers or with additional piping of a sufficient
length to prevent access to the impeller!
4.3 Connecting the pump-motor unit to the
system
4.3.1 Important notes
Delivery direction of the gases
The pumped gases are sucked in via the inlet
connection and discharged via the discharge
connection.
The delivery direction of the gases is marked by
arrows on the connections:
The inlet connection with the corresponding
muffler is marked by an arrow pointing into the
pumpmotor unit.
The discharge connection with the
corresponding muffler is marked by an arrow
pointing out of the pumpmotor unit.