Manual
Shutting Down and Measures for Prolonged Standstill
© Gardner Denver Deutschland GmbH 23 / 30 610.44431.40.000
i
IMPORTANT!
If the storage period exceeds one
year the life expectancy of the bear-
ings might be reduced.
Measures after shutdown / before storage:
Seal up the suction and delivery branches.
Provide loose lead ends with an ESD-
prevention bag.
Ensure the correct storage conditions (see
below).
Storage conditions:
Ambient temperature -20°C...+70°C
(-4°F…+158°F)
Relative humidity 10% ... 95%
Atmospheric pressure 500 hPa ... 1,100 hPa
Vibrations see section 3, "Technical
Data", page 6.
Measures before recommissioning after stor-
age:
Make sure that there is no oxide layer on the
contacts. If necessary, remove oxide layer.
Make sure that the insulation of the electrical
connecting cable has not become porous.
8 Shutting Down and Measures for Prolonged Standstill