Owner's manual

7
www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH |
Sicherheit
2.3 Designated use
The machine must only be operated in such areas
as are described in the operating instructions:
only operate the machine in a technically perfect
condition
do not operate the machine when it is only par-
tially assembled
the machine must only be operated at an ambi-
ent temperature and suction temperature of
between 5 and 40°C. Please contact us for
temperatures outside this range.
the machine may convey, compress or extract
the following media:
all non-explosive, non-infl ammable, non-ag-
gressive and non-poisonous dry gases and
gas air mixtures
2.4 Unacceptable operating modes
extracting, conveying and compressing explo-
sive, infl ammable, aggressive or poisonous me-
dia, e.g. dust as per ATEX zone 20-22, solvents
as well as gaseous oxygen and other oxidants,
water vapour, liquids or solid materials
must not be operated in rooms that are at risk
of explosion and in Zone 22 dusty atmospheres
that are at risk of explosion
using the machine in non-commercial plants if
the necessary precautions and protective meas-
ures have not been taken in the plant
installing in environments that are at risk of ex-
plosions
using the machine in areas with ionising radia-
tion
modifi cations to the machine and accessories