SYSTEM SPECIFICATIONS
7200 EXM Monitor
Max Flow Rating 1250 GPM (4731 LPM)
Max Operating Pressure 250 PSI Continuous (17.2 BAR)
500 PSI Limited Duty (34.5 BAR)
[50% / 1hr (30min on / 30 min off)]
Inlet Size 3”-150# Flange, DN80-PN16 Flange, 4”-150# Flange,
3” NPT, 3” BSPT
Outlet Size 2.5” Male NHT, 2.5” Male BSPP
Travel V: -45° to +12
H: L175° to R175°
Movement Sealed Electric Motors
Swing Radius 6”
Stow Height 16”
Weight 31 Lbs.
Operating temperature range -40°F to +185°F (-40°C to +85°C)
Environmental Rating NEMA 4
Monitor Controller
Input power 12/24 VDC (11-27 VDC)
Control Communication CAN bus J1939
2.4 Ghz digital radio frequency (unlicensed)
Electrical Load See Table 1 Below
Fuse Rating 20 AMPS (12V) & 10 AMPS (24V)
RF power output Meets FCC part 15 requirements for license free operation
Operating temperature range -40
o
F to +185
o
F (-40
o
C to +85
o
C)
Environmental Rating NEMA 4
FCC ID KQL-2510100
7200 SD Standard Duty Motors
Motor (12 VDC)
Left/Right
Up/Down
Nozzle
Run Current
3 A
3 A
0.5 A
Stall Current
10 A
10 A
NA
Current Trip Point
6.5 A
6.5 A
4 A
7200 HD Heavy Duty Motors
Motor (12 VDC)
Left/Right
Up/Down
Nozzle
Run Current
5 A
5 A
0.5 A
Stall Current
70 A
70 A
NA
Current Trip Point
20 A
20 A
4 A
Table 1: Motor Current Specifications
Panel Mount Controller - 7010
Input power 12/24 VDC (11 VDC to 27 VDC)
Electrical Load 0.5 AMPS
Fuse Rating 1 AMPS (12V) & 0.5 AMPS (24V)