Specification Sheets
5 15/16"
150mm
27
686mm
ADA
REQUIREMENT
3"
77mm
18 9/16"
472mm
31 1/2"
800mm
RIM
HEIGHT
32 9/16"
827mm
ORIFICE
HEIGHT
39 1/16"
992mm
ORIFICE
HEIGHT
C
C
L
L
C
12 5/8"
320mm
18 3/4"
476mm
20 1/8"
511mm
25 1/8"
638mm
3 1/2"
89mm
4 1/2"
114mm
5"
127mm
1 3/8"
35mm
1 3/8"
35mm
5 3/4"
146mm
5 3/4"
146mm
1 3/8"
35mm
1 3/8"
35mm
5 3/4"
146mm
5 3/4"
146mm
18 5/16"
465mm
19 1/8"
486mm
2 7/16"
63mm
1 9/16"
40mm
10"
254mm
5"
127mm
36 1/8"
918mm
6 1/2"
165mm
E
F
D
A
B
F
F
FINISHED FLOOR
HANGER BRACKETS
8 1/8"
206mm
6 1/2"
166mm
5/16" DIA. (10 HOLES)
36 1/2"
927mm
RATED FOR INDOOR AND OUTDOOR USE
Open space rough-in design permits new installation or replacement of existing fountains and
coolers with this Elkay cooler when rough-in is within the outline shown.
NOTICE
This water cooler must be connected to the water supply using a dielectric coupling.
The cooler is furnished with a non-metallic strainer which meets this requirement.
The drain trap which is provided by the installer should also be plastic to completely
isolate the cooler from the building plumbing system.
IMPORTANT! INSTALLER PLEASE NOTE:
These units are designed and built to provide water to the user which has not
been altered by materials in the cooler waterway. The grounding of electrical
equipment such as telephone, computers, etc. to water lines is a common
procedure. This grounding may be in the building but may also occur away from
the building. This grounding can cause electrical feedback into a water cooler
creating an electrolysis which results in a metallic taste or an increase in the
metal content of the water. This condition is avoidable by installing the cooler
using the proper materials as shown.
ROUGH-IN DIMENSIONS
Heavy-Duty, 14 Gauge Wall-Mount Water Cooler
Vandal-Resistant, Barrier Free Access
Model VRCHDTL8S*C
REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER
LEGEND:
A = Recommended Water Supply location. Shut-off Valve (not furnished) to accept
3/8” O.D. unplated copper tube. Up to 3” (76mm) maximum out from wall.
B = Recommended Waste Outlet location. To accommodate 1-1/2” nominal drain.
Drain stub 2” (51mm) out from wall.
C = 1-1/2” Trap (not furnished).
D = Electrical Supply (3) Wire Recessed Box Duplex Outlet.
E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet
louvers to wall.
F = 7/16” (11mm) Bolt Holes for fastening to wall.
NOTE: Installations Must Use Ground Fault Circuit Interrupter (GFCI).
Job Name: ____________________________________
Model: _______________________ Qty. ____________
Contact: ______________________________________
Approval Signature: _____________________________
Notes:
Printed in U.S.A.
© 2014 Elkay
2222 Camden Court
Oak Brook, IL 60523
630-572-3192
elkay.com
Page 3
1/4” O.D. TUBE
WATER INLET
TO COOLER
3/8” O.D. TUBE CONNECT
COLD WATER SUPPLY
BUILDING WATER
INLET
NOTE: WATERFLOW
DIRECTION
SERVICE STOP
(NOT FURNISHED)
B CA
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
A B C