Use and Care Manual

0000001030 (Rev. G - 01/18)
ERPBD28WSC LRPBD2_8WSC
Page 4
Figure 4 - Fountain Installation
Figure 5 - Lower Panel Installation
8. Install reset switch for bottle ller (Fig 4). Connect the switch
wire to the extension wire on the back of the bottle ller. Wrap
up the excess cord.
9. Attach waste tubes (1-1/4” O.D.) to 1-1/4” O.D. slip trap. Trap
on the bottle ller side must be 1-1/2” O.D. (provided by
others).
10. Make nal water supply connections.
11. These products are designed to operate on 20-105 PSI
supply line pressure. If inlet pressure is above 105 PSI,
a pressure regulator must be installed in the supply line.
(Caution: Any damage caused by connecting these products to
a supply line with pressure lower than 20 PSI or higher than
105 PSI IS NOT covered under warranty.)
12. Make electrical connections to the bottle ller and remote
chiller. The LCD Bottle counter should illuminate.
13. Verify proper dispensing from the bottle ller by placing a cup,
hand or any opaque object in front of sensor area and verify
water dispenses. Note: the rst initial dispenses might have air
in the line which may cause a sputter. This will be eliminated
once all air is purged from the line. A steady stream of water
assures all air is removed. The sensor has a 20 second maxi
mum ON time. It may be necessary to step away from the
beam a few times to purge all air. Check for leaks.
14. Check stream height from bubbler. Stream height is factory
set for 35 PSI supply. If supply pressure varies greatly from
this, remove push button (Item 7 - Figure 8) and adjust the
screw on the regulator (Item 8 - Figure 8). To remove push but
ton, remove setscrew from bottom of sleeve (Item 21). Insert a
small punch in screw hole and push up while grasping the
push button and pull forward removing the push button. Clock
wise adjustment will raise stream height and counterclockwise
movement will lower stream height. For best adjustment
stream should hit basin approximately 6-1/2” from the bubbler.
Reassemble the push button by pushing in on button until the
push button catches in the sleeve. Reinstall the setscrew (Item
21) in the sleeve (Item 6).
15. Install the cover plates.
16. Install the bottom panel, tighten screws (Fig 4).
17. Optional: Mount optional panels. Slide tongue of panel under
edge of already installed panel. Tighten screws.
20
18
17
16
24
23
View From Rear
5
NOTE:
When installing replacement bubbler and pedestal (Fig 6), tighten
locknut only to hold parts snug in position. Do Not overtighten.
Figure 6 - Flexi-Guard
®
Bubbler Details
Basin
1
Locknut
23
26
Reset
Switch
Back
Panel
27,28,29,30,31