Installation Sheet
INSTRUCTIONS TO ACCESS PROGRAMMING BUTTON
1) Remove lower cover on refrigerated unit by removing (4) screws.
2) Button is located in lower right corner of unit (See Fig. 13).
Programming
Button
FIG. 13
Filter Label
Location
FIG. 12
INSTRUCTIONS FOR REPLACING FILTERS
1) Remove lower cover on left hand unit by removing (4) screws (See Fig. 5, Pg. 6).
2) Turn off water supply; dispense water to relieve pressure.
3) Remove power by unplugging cooler.
4) Turn used lter counterclockwise 1/4 turn to remove from lter head.
5) Remove cap from new lter and use to seal used lter.
6) Insert new lter into existing lter head and turn fully clockwise. Make sure you can read the label on the front of the lter once it is installed.
(See Fig. 16 on Pg. 19).
7) Plug in unit to restore power.
8) Turn on water supply and run a minimum of two gallons of water through the lter to purge air any ne carbon particles from lter. Also run
water through bottle ller.
Note: Filter status light will automatically reset once new lter is installed.
FINAL INSTALLATION (FILTER)
21) Remove lter from carton, remove protective cap, attach lter to lter head by rmly
inserting into head and rotating lter clockwise. Ensure that lter label can be read when
lter is installed. (See Fig. 12)
22) Turn water supply on and inspect for leaks. In both cooler and Bottle Filler. Fix all leaks
before continuing.
23) Once cooler and bottle lter have been inspected for leaks and any leaks corrected,
plug cooler into wall.
24) Reinstall two mounting screws from rst step above. Caution do not over tighten screws.
25) Once power is applied to the cooler the GREEN LED light will illuminate on the bottle
ller showing good lter status along with the LCD Bottle Counter.
26) Verify proper dispensing by placing cup, hand, or any opaque object in front of sensor
area and verify that the water dispenses. Note: the rst initial dispenses might have air
in line which may cause a sputter. This will be eliminated when all air is purged from the
line.
27) Once unit tests out, install Lower Panels back on water coolers. (See pages 12-13 for
versatile wrapper installation). Units are now ready for use.
Back of Filter
Page 8
ENLZSTL8WS_1G
1000004543 (Rev. C - 07/19)