Installation Sheet

BOTTLE FILLER INSTALLATION
14) Remove two (2) mounting screws with 5/32” Allen wrench holding Bottle Filler to wall mounting plate (See Fig. 8). Note do not discard mounting
screws, they will be needed to secure Bottle Filler to wall mounting plate.
15) Remove wall mounting plate from Bottle Filler (see Fig. 8 ). Place wall mounting plate against wall on top of basin. Center the wall mounting plate side
to side with the basin. Mark the six (6) mounting holes with a pencil (See Fig. 1, Pg. 2). Place tape over wiring harness conection on top of cooler to
prevent debris from falling into Connection(See Fig. 6, Pg. 9).
16) Remove wall mounting plate from wall. NOTE: Mounting plate MUST be supported securely. Add xture support carrier if wall will not provide
adequate support.
17) Install wall mounting plate to wall using six (6) 7/16” obround mounting holes (mounting
bolts not included) (See Fig. 7, Pg. 9). Use appropriate fasteners for your wall type.
18) Install gasket on bottom of Bottle Filler with gasket support bracket & (2) screws.
(See Fig. 8).
FIG. 11
34
33
32
Gasket removed from bottle ller for clarity.
Mounting Bolt Holes
Walll Mounting Plate
Bottle Filling Unit
19) Route 3/8” tubing through the opening in the bottle ller gasket and plug into bulkhead tting in basin. Route the wiring harness through the
gasket and plug into the connector on the top of the basin.
20) Place Bottle Filler on the four (4) hooks on the mounting plate installed on wall.
FIG. 8
Fig. 10
Gasket removed from bottle ller for clarity.
Fig. 9
Page 7 1000004543 (Rev. C - 07/19)
ENLZSTL8WS_1G