Installation Sheet
Page 10
ENLZSTL8WS_1G
1000004543 (Rev. C - 07/19)
FIG.17
FIG.18
Swap drain parts in shroud: Loosen each hose clamp retaining the drain pieces. Remove each drain piece and swap to other basin.
Tighten each hose clamp.
Non-Refrigerated Cooler side:
Carefully tip the shroud/basin assembly
toward the cooler frame.
Connect one of the black wires to the
solenoid valve and one to the power
cord.
Re-connect the water line at the
solenoid. Reference (Fig. 21, p.14) for
the operation of the quick connect
ttings.
Refrigerated Cooler side:
Carefully lift and tip the shroud/basin
assembly off the cooler frame.
Only disconnect the (2) black wires
coming from the shroud assembly that
go to the solenoid valve and to the cold
control.
Disconnect the water line at the solenoid
valve. Reference (Fig. 21, p.14) for the
operation of the quick connect ttings.
Enhanced EZH2O Error Codes
Error
Code
Error Description Corrective Action
Please clear Bottle Filler • Remove obstruction
• Clean lens on IR sensor
• Unplug unit for at least 30 seconds and restart
• If error repeats, replace IR sensor
E013 Missing or Incomplatible Filter • Check that lter is installed correctly (label facing forward, round blue tag facing NFC Board)
• Unplug unit for at least 30 seconds and restart
• Replace lter
• Replace lter head assembly with repair kit
• If error repeats, contact certied service professional
EO13
&
EO14
Missing/Unplugged NFC
Board
• Unplug unit for at least 30 seconds and restart
• Verify cable connector is plugged into NFC board on lter head assembly
• Replace lter head assembly with repair kit
• If error repeats, contact certied service professional