Instructions / Assembly
Enhanced EZH2O Error Codes
Error
Code
Error Description Corrective Action
E01 Bottle ller area obstructed • Clean lens on IR sensor
• Unplug unit for at least 30 seconds and restart
• If error repeats, replace IR sensor with 1000002434 KIT - IR SENSOR
E02 Missing or Incomplatible Filter • Check that lter is installed correctly (label facing forward, white tag fac-
ing back)
• Unplug unit for at least 30 seconds and restart
• Replace lter
• Replace lter head assembly with repair kit - 1000002030 KIT - FILTER
HEAD-BRKT-FTGS
• If error repeats, contact certied service professional
E03 Missing NFC Board • Unplug unit for at least 30 seconds and restart
• Verify cable connector is plugged into NFC board on lter head assembly
• Verify cable connector is plugged into control board (10 pin connector on
harness # 0000001225)
• Replace lter head assembly with repair kit - 1000002030 KIT - FILTER
HEAD-BRKT-FTGS
• If error repeats, contact certied service professional
Page 10
ENLZS8WS_1G
1000004538 (Rev. A - 09/18)