ENLZS8WS_1G Enhanced INSTALLATION & USE MANUAL LZ ™ Series Bottle Filling Stations & Coolers Page 1 1000004538 (Rev.
1000004538 (Rev. A - 09/18) E Fig.
ENLZS8WS_1G HANGER BRACKET INSTALLATION 1) Remove hanger bracket fastened to back of cooler by removing one (1) screw 2) Mount the hanger bracket as shown in Figure 1 (Pg. 2) NOTE: Hanger Bracket MUST be supported securely. Add fixture support carrier if wall will not provide adequate support. Anchor hanger securely to wall using all six (6) 1/4 in. dia. mounting holes. IMPORTANT: 5-7/8 in. (150mm) dimension from wall to centerline of trap must be maintained for proper fit.
ENLZS8WS_1G Secure cooler frame to wall by installing (2) screws and washers (not supplied). FIG. 2 FIG. 3 Lay gasket along back of bottle filler mounting plate. Align BF and lay on cooler basin. Fig. 4 Attach the 3/8 water line into the bulkhead fitting Fig. 5 1000004538 (Rev.
ENLZS8WS_1G Fig. 7 Connect the bottle filler electrical harness Fig. 6 34 33 MOUNTING BOLT HOLES (6) 35 WALL MOUNTING PLATE BOTTLE FILLING UNIT Fig. 8 Page 5 1000004538 (Rev.
ENLZS8WS_1G 115V Refrigerated Wiring Diagram with Alpha/Numeric Display 29 28 30 31 26 Fig. 9 Superseal Fitting Assembly OPERATION OF OF QUICK OPERATION QUICKCONNECT CONNECTFITTINGS FITTINGS A A A SIMPLY PUSHIN IN SIMPLY PUSH TUBE TO TUBE TOATTACH ATTACH TUBE TUBEIS IS SECURED SECURED INPOSITION POSITION IN B C Note: Screw the locknut hand tight to seal Fig. 10 1000004538 (Rev. A - 09/18) Fig.
ENLZS8WS_1G 11 Basin Locknut BUBBLER DETAIL NOTE: Fig. 13 When installing replacement bubbler and pedestal, tighten nut only to hold parts snug in position. Do Not Overtighten. Filter Label Location Fig. 12 3 2 1 Fig. 14 WATERSENTRY® Filter Detail WATERSENTRY® FILTER PARTS LIST ITEM NO. PART NO. 1 2 51300C 1000002030 3 1000002443 DESCRIPTION Filter Assy - 3000 Gal.
ENLZS8WS_1G Service Instructions Lower and Upper Shroud 11 To access the refrigeration system and plumbing connections, remove four screws from bottom of cooler to remove the lower shroud. To remove the upper shroud for access to the pushbars, regulator, solenoid valve or other components located in the top of the unit, remove lower shroud, disconnect drain, remove four screws from tabs along lower edge of upper shroud, unplug two wires and water tube. Fig.
Action Momentary Momentary Momentary Momentary Momentary Momentary Momentary Momentary Top level Info Info Set time Filter Refrig Range Page 9 B-Light EnerSave Momentary Momentary 75% 100% On Momentary Momentary Momentary 50% Off Momentary 25% Momentary Momentary Yes 1-10 Momentary No Momentary Momentary Min 0-69 in 5 minute increments Yes Momentary Hour (12 hour) Momentary Momentary No Momentary AM/PM Action Day (Sunday-Saturday Flashes error code Scrolls t
ENLZS8WS_1G Error Code Enhanced EZH2O Error Codes Error Description E01 E02 E03 1000004538 (Rev.
ENLZS8WS_1G Pictured is unit only without bottle filler. Note: Danger! Electrical shock hazard. Disconnect power before serviceing unit. Uses HFC-134A refrigerant 14 1 22 Filter Location 16 24 8 9 27 6 5 See Fig. 13 12 or 13 2 3 See Fig. 15 12 12 20 17 Adjust for stream height 22, 25 7 10 32 15 19 20 21 18 4 20 Fig. 18 Page 11 1000004538 (Rev.
ENLZS8WS_1G 115V PARTS LIST ITEM PART NO. NO.