Specification Sheet
A
F
E
B
E
O
9/32"
7mm
(6)
21 7/8"
5
56mm
17 7/16"
443mm
19"
483mm
2"
51mm
3 7/8"
98mm
7"
178mm
7"
178mm
13 15/16"
354mm
28 13/16"
732mm
2"
51mm
6 3/8"
162mm
6 3/8"
162mm
18 3/8"
467mm
‰
D
C
12 1/2"
318mm
3"
77mm
2"
51mm
27"
686mm
ADA
REQUIREMENT
31 5/16"
796mm
RIM
HEIGHT
32 7/8"
835mm
ORIFICE
HEIGHT
HANGER BRACKET
19"
484mm
FILTER
FILTER
5 3/4"
146mm
5 7/8"
150mm
8 1/16"
205mm
FINISHED FLOOR
RATED FOR INDOOR USE ONLY
REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER
Hands-Free
®
Sensor-Activated Wall Mount Water Cooler
Filtered with LED Visual Filter Monitor
Model LZO8 and LZOD
ROUGH-IN DIMENSIONS
NOTICE
This water cooler must be connected to the water supply using a dielectric coupling.
The cooler is furnished with a non-metallic strainer which meets this requirement.
The drain trap, which is provided by the installer, should also be plastic to completely
isolate the cooler from the building plumbing system.
Open space rough-in design permits new installation or replacement of existing
fountains and coolers with this Elkay cooler when rough-in is within the outline shown.
IMPORTANT! INSTALLER PLEASE NOTE:
This water cooler has been designed and built to provide water to the user which has
not been altered by materials in the cooler waterways.
The grounding of electrical equipment such as telephone, computers, etc to water
lines is a common procedure. This grounding may be in the building or occur away
from the building. This grounding can cause electrical feedback into a water cooler
creating an electrolysis which creates a metallic taste or causes an increase in the
metal content of the water. This condition is avoidable by installing the cooler using
the proper materials as shown below.
LEGEND:
A = Recommended Water Supply location. Shut-off Valve (not furnished) to accept
3/8” O.D. unplated copper tube. Up to 3” (76mm) maximum out from wall.
B = Recommended Waste Outlet location. To accommodate 1-1/4” nominal drain.
Drain stub 2” (51mm) out from wall.
C = 1-1/4” Trap (not furnished).
D = Electrical Supply (3) Wire Recessed Box Duplex Outlet.
E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet
louvers to wall.
F = 7/16” (11mm) Bolt Holes for fastening to wall.
NOTE: New Installations Must Use Ground Fault Circuit Interrupter (GFCI)