Installation Sheet

SPOUT ASSEMBLY
CARTRIDGE NUT
CARTRIDGE/VALVE
HANDLE
ALIGNMENT
SCREW
HANDLE
INSTALL
FLANGE
FLANGE GASKET
LOCK NUT
TEMPERATURE
INDICATOR
RING
LOGO
SET SCREW
SPACER
RING
WEDGE
Elkay recommends installation by a licensed plumber.
Install Spray and Hose (if included)
1. Remove locknut and washer from sprayer base assembly and
place assembly in far right hole of sink deck. Reassemble washer
and locknut on shank from under sink. Tighten.
2. Insert hose through sprayer base assembly then route back up
through the center hole for the faucet. Thread hose onto faucet
and tighten.
Install Faucet
1. Be sure mounting surface is clean and dry.
2. Prepare waterway; Make sure handles, cartridge nuts and flanges
are removed and the locknuts are threaded down to the bottom.
3. From under sink, insert waterway assembly up through sink faucet
drillings. From topside, Put flange gaskets on waterway, then thread
flanges onto waterway with about 1/8” of threads showing.
4. Thread cartridge nuts onto cartridges and tighten.
5. Unscrew the flanges until they are snug against the cartridge nuts.
6. From under sink, tighten locknuts against sink.
7. Place spacer ring and wedge inside waterway spout connector. (See
Change Faucet Rotation procedure)
8. Thread spout assembly on waterway and hand tighten.
9. Connect supply lines to faucet shanks and tighten.
10. Remove aerator from spout and Flush water lines to remove dirt and
sediment from water lines. Replace aerator.
Install Handles (if required)
1. Ensure cartridge (valve) is in the “off” position. (Fully counter
clockwise for Cold and Fully clockwise for Hot.)
2. Insert handle over cartridge stem
3. Insert alignment screw in handle hole towards back of sink. Screw
in only half way.
4. Place Red Temperature Indicator Ring in the top of the hot side
handle and the Blue ring in the top of the Cold side handle.
5. Place Logo part in top of both handles so logo can be read from
front of sink.
6. Thread handle set screw into each handle and tighten.
Change Faucet Rotation
1. Unscrew spout and pull upward to remove.
2. Using a finger, reach inside the waterway and pull out the wedge and
spacer ring.
3. Select the spacer ring with the desired rotation and insert into waterway.
4. Install the wedge into the waterway, making sure to align the two different
size “keys” (slots) inside the waterway with those on the wedge. (It would
help to use long nose pliers to seat the wedge, however, placing the wedge
on a finger and guiding it into the waterway also works.) Angle small side of
wedge to contact key slot first. Rest wedge in place on spacer ring. See
FIGURE 1.
5. Make sure the white wear ring is seated around the base of the spout.
Push the spout straight into the waterway, aligned 90° from handles.
6. Thread spout base onto waterway and Rotate the spout several degrees left
and right while hand tightening
FIGURE 1