Screw quick connect assembly to the free end of pull-out
hose. Align male fitting (1) and tabs (2) on quick connector.
Push quick connector housing firmly upward and snap
onto male fitting. Pull down moderately to ensure
connection has been made.
After connecting the hose, attach weight (3) to hose at
bottom of loop to prevent hose from twisting and return
hose to proper position.
Important: after installation is completed, turn on hot
and cold water supplies. Pull the hose assembly out of
the spout and remove the spray head by unscrewing it
from the hose counterclockwise. Be sure to hold the
end of the hose down into the sink and turn the faucet
on to the warm position where it mixes hot and cold
water. Flush water lines for one minute. Check for
leaks. Re-tighten any connections if necessary, but do
not overtighten. Reinstall spray head by hand
tightening it back onto the spray hose.
Make connections to water lines.
Use 1/2" I.P.S. faucet connections (1) or use coupling
nuts (3) with 3/8" O.D.ball-nose riser (2). Use
wrenches to tighten connections. Do not overtighten.