Specification Sheet
O
14"
356mm
6 - O .500 HOLES
EQUALLY SPACED
ON A
O
12.00" B.C.
29"
737mm
H G
PVC COLUMN CENTERED
BETWEEN MOUNTING
BOLT HOLES
Printed in the U.S.A.
Page 2
MODEL LK4410BFFRK
Outdoor Tubular
Bottle Filling Station
OPERATING PRESSURES:
Supply water 20 – 105 psi maximum
MOUNTING INSTRUCTIONS and
PLUMBING INSTRUCTIONS
Site and drainage excavation is required for fountain installation. Refer
to owner’s manual for site preparation details. Provide solid, well-drained
surface to mount pedestal fountain (concrete pad recommended) with
adequate support (300 lb. load minimum). (6) 3/8” minimum fasteners
(not included) should be attached securely to mounting surface in order
to secure fountain, (Refer to rough-in diagram), and be sure to allow
an opening for the freeze-resistant valve in the ground as shown in the
installation instructions that accompany the fountain. (Refer to the rough-in
diagram below). Refer to local codes for any additional requirements.
Locate and install plumbing through ground as required. Assemble
fountain to prepared site and mounting pad.
NOTE: Fountain is not furnished with service valve.
Position pedestal over plumbing and secure base to fasteners. Remove
access panels and connect supply and water lines. Turn on water supply
and check for leaks. Refer to owner’s manual for detailed instructions.
Reassemble access panels to pedestal. Trap and service stop not
included.
TOP VIEW
2222 Camden Court
Oak Brook, IL 60523
630-572-3192
elkay.com
57
"
1448mm
19"
483mm
3"
76
mm
1
4 9/
16"
371mm
G
B
A
A
4"
102mm
10"
254mm
27"
686mm
37"
940mm
F
E
J
D
H
E
C
8"
203mm
27 5/16"
694mm
WATER INLET
DRAIN LINE
*
SIDE & FRONT VIEWS
* ADA Requirement
LEGEND
A = ACCESS PANEL (8” X 10”)
B = REMOVABLE BOTTOM COVER
C = 1” PVC DRAIN
D = PRESSURE FITTING 1-1/4” x 3/4”
E = CONNECTOR 1-1/4” to 1-1/4”
F = 1-1/4” DRAIN TUBE
G = AIR CONTROL LINE
H = 1/4” WATER LINE
J = CONNECTOR FOR AIR CONTROL LINE
4"
102m
m
FROST
LINE
5 CUBIC FEET
POROUS FILL
( LARGE BROKEN FILL )
DRAIN LINE BY INSTALLER
( AS REQUIRED BY LOCAL CODES )
WATER INLET LINE
( BY INSTALLER )
CONCRETE SLAB
BACK FILL
( DIRT )
21"
533mm
MIN.
FROST LINE DEPTH
DEPENDANT ON
GEOGRAPHIC
LOCATION AND
LOCAL
REQUIREMENTS
12"
305mm
FILL LINE
MIN.
SITE PREPARATION
DETAIL
36” Minimum
67” Maximum