Installation Guide
(630) 574-8484 13 Elkay Manufacturing Company
1000005232 (Rev. C - 05/19) Built-in Filtered Water Dispenser
3. Connect a 3/8 inch water supply line, copper or
plastic, to the quarter-turn shutoff valve.
4. Connect a 1/4 inch insulated water line, copper or
plastic, to the outlet connector of the lter.
5. Connect the 1/4 inch insulated water line to either a
remote chiller or the 1/4 inch water line on the water
dispenser. Use a union connection tting to connect
the water line to the water dispenser.
NOTICE
Do not disconnect the 1/4 inch
tubing from the water valve at
the top of the water dispenser. This connection has
been factory tested to be leak-free and could result in
water leaking into the unit if this connection is
changed.
6. If a remote chiller is installed, follow the installation
instructions provided with that unit.
4.8 Remote Water Chiller
A remote water chiller can be installed in connection with
the water dispenser to supply chilled water. The chiller
must be installed within 15 feet of the water dispenser, in
an accessible location. Install the chiller with adequate
ventilation space as outlined in the water chiller manual.
The standard installation of the built-in water dispenser
supplies ltered water at the ambient temperature of the
water supply that comes into the unit. This temperature
can vary greatly depending on the location of the
incoming water line.
Follow the installation instructions that come with the
water chiller. A lter unit must also be installed prior to
the chiller, and the water line from the chiller to the water
dispenser cannot be more than 15 feet long. When the
lter is located in a remote location, mount the lter
vertically on a wall or other supporting structure near the
chiller.
Water
Filter
Water
Chiller
Water
Dispenser
Note: The remote chiller can take from 24 to 48 hours
to provide completely chilled water. Water lines must be
insulated to prevent condensation.
5. Startup
1. Open the shutoff valve(s) for the water supply. Check
for any water leaks.
2. Place the ON/OFF switch in the upper left-hand corner
of the water dispenser opening in the OFF position.
Turn ON power to the unit (typically a circuit breaker).
3. Move the power switch to the ON position and make
sure the LED lights are lit.
4. Remove the scratch resistant protective layer that is
covering the glass face, lter cover, and back wall
covering.
Note: Not removing this layer will activate the IR sensor.