Specification Sheet
Printed in U.S.A.
© 2015 Elkay
18 3/4"
476mm
4 1/2"
114mm
52 1/8"
1324mm
3"
76mm
HOOK RODS (2)
P/N 101567443730
FRAME
5/16" SCREWS OR BOLTS
(10 REQ'D - NOT FURNISHED)
INSTALL (2) SCREWS
(P/N 111008343890) IN FRAME
BEFORE INSTALLING IN OPENING
FINISHED FLOOR
4 1/2"
114mm
27"
686mm
ADA
REQUIREMENT
8"
203mm
28 3/4"
730mm
1 5/8"
41mm
11"
279mm
1 1/8"
29mm
33 15/16"
862mm
5/8"
16mm
12"
305mm
SPACE REQ'D
BEHIND STUD WALL
1-1/4" (32mm)
WASTE TUBE
FURNISHED
BOTTLE FILLER
DRAIN
ELECTRICAL
INLET
3/8" O.D. COPPER TUBE
WATER INLET ON
CHILLER. SHUT OFF
VALVE BY OTHERS
1/4" O.D. COPPER
TUBE. COLD WATER
OUTLET
20 1/2"
520mm
34 5/8"
880mm
9 7/8"
252mm
19 3/4"
502mm
37 1/4"
947mm
44"
1119mm
18 3/8"
467mm
ACTIVATION
SENSOR
ROUGH-IN DIMENSIONS
No Lead Two-Level SwirlFlo
®
Wall Mount, Barrier-Free Refrigerated Fountain
with EZH2O
®
Bottle Filling Station
Model EZWS-ERPBM8K
INSTALLER NOTE:
THIS DRINKING FOUNTAIN IS FURNISHED
WITH A BUBBLER AND VALVE INCLUDING
ALL CONNECTING FITTINGS WHICH ARE
MANUFACTURED OF COMPLETELY LEAD
FREE MATERIAL. SHUTOFF VALVE (NOT
FURNISHED) TO ACCEPT 3/8” O.D. UNPLAT-
ED COPPER TUBE.
MOUNTING INSTRUCTIONS
Refer to rough-in for location of plumbing and
electrical sources. The support frame is to be
installed rst. Hang upper panel to hanger on
frame. Fountain is to be attached to panel and
wall frame. Water service line, waste line and
electrical are assembled as required. Perform
a nal check for leaks and correct function of
fountain and chiller. (For details see the instal-
lation instructions.)
Installation requires trap to be installed in
wall. Trap and service stop not included.
WALL OPENING
IMPORTANT: It is necessary to create a wall
opening 18 ¾” W x 52 ⅛” H and 4 ½” above
the oor line.
ELECTRICAL DATA
Junction box for a (3) wire 10 AMP branch
circuit. Standard 120 Volt, 60 Hz, single phase.
Electrical outlet, three (3) conductor grounded.
Locate within safe reach of power cords.
Job Name: ______________________________
Date: __________________ Qty. ____________
Contact Info (Name, Phone, Email): __________
________________________________________
________________________________________
Approval: _______________________________
**NEW INSTALLATIONS MUST USE GROUND FAULT CIRCUIT INTERRUPTER *GFCI)
SIDE VIEW
FRONT VIEW
WALL LAYOUT
B CA
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
A B C
1/4” O.D. TUBE
WATER INLET
TO COOLER
3/8” O.D. TUBE CONNECT
COLD WATER SUPPLY
BUILDING WATER
INLET
NOTE: WATERFLOW
DIRECTION
SERVICE STOP
(NOT FURNISHED)