Installation Sheet
1000002504 (Rev. F - 03/19)
ERPBD8WSC LRPBD8WSC
Page 4
Figure 4 - Fountain Installation
Figure 5 - Lower Panel Installation
8. Install fountains with (4) 5/16-18 HHMS, (4) 5/16-18 nuts &
(2) support brackets (provided) (Fig. 4). Connect the ¼” water
line from fountain to the remaining opening on the tee at the
remote chiller (cut lines to t as needed), (Test t refrigerated
panel to make sure there is a tight joint between it & the main
panel before fully tightening mounting screws.)
9. Attach waste tubes (1-1/4” O.D.) to 1-1/4” O.D. slip trap. Trap
on the bottle ller side must be 1-1/2” O.D. (provided by
others).
10. Make nal water supply connections.
11. These products are designed to operate on 20-105 PSI
supply line pressure. If inlet pressure is above 105 PSI,
a pressure regulator must be installed in the supply line.
(Caution: Any damage caused by connecting these products to
a supply line with pressure lower than 20 PSI or higher than
105 PSI IS NOT covered under warranty.)
12. Make electrical connections to the bottle ller and remote
chiller. The LCD Bottle counter should illiminate.
13. Verify proper dispensing from the bottle ller by placing a
cup, hand or any opaque object in front of sensor area and
verify water dispenses. Note: the rst initial dispenses might
have air in the line which may cause a sputter. This will be
eliminated once all air is purged from the line. A steady stream
of water assures all air is removed. The sensor has a 20
second maximum ON time. It may be necessary to step away
from the beam a few times to purge all air. Check for leaks.
14. Check stream height from bubbler. Stream height is factory
set for 35 PSI supply. If supply pressure varies greatly from
this, remove push button (Item 7 - Fig. 8) and adjust the
screw on the regulator (Item 8 - Fig. 8). To remove push but
ton, remove setscrew from bottom of sleeve (Item 21). Insert a
small punch in screw hole and push up while grasping the
push button and pull forward removing the push button. Clock
wise adjustment will raise stream height and counterclockwise
movement will lower stream height. For best adjustment
stream should hit basin approximately 6-1/2” from the bubbler.
Reassemble the push button by pushing in on button until the
push button catches in the sleeve. Reinstall the setscrew (Item
21) in the sleeve (Item 6).
15. Install the cover plate.
16. Install the bottom panel, tighten screws (Fig. 5).
20
18
17
16
24
23
View From Rear
5
Figure 6 - Flexi-Guard
®
Bubbler Detail
Basin
1
Locknut
13
Reset
Switch
Back
Panel
26,27,28,29,30
NOTE:
When installing replacement bubbler and pedestal tighten
locknut only to hold parts snug in position. Do Not over-
tighten.
Figure 4A