Specification Sheet
Printed in U.S.A.
© 2015 Elkay
38 1/2"
978mm
9
7/8
"
251mm
8" (203mm) MIN
IMU
M
12" (305mm) RECOMME
N
DE
D
FOR DRAIN CONNECTION
AND ACCESS TO
BOTTLE FILLER
ELECTRICALS
5/8"
16mm
18 3/8"
467mm
1 5/8"
41mm
1 5/8"
41mm
OPTIONAL ACCESS
PANEL
OPTIONAL ACCESS
PANEL
BOTTLER FILLER
DRAIN
1-1/2" IPS
WASTE LINE
3/8" IPS
SUPPLY
34 5/8"
879mm
44 3/4"
1137mm
16 1/2"
419mm
21 1/2"
546mm
28 3/4"
729mm
36 1/2"
927mm
27"
686mm
ADA
REQUIREMENT
33 15/16"
862mm
41 11/16"
1058mm
18 11/16"
475mm
ACTIVATION
SENSOR
BOLT FRAMES TOGETHER
WITH 5/16" X 3/4" (19mm) BOLTS
(4 REQ'D - PROVIDED)
P/N 111577243890
INSTALL (2) SCREWS
(P/N 111008343890) IN FRAME
BEFORE INSTALLING IN OPENING
5/16" HEX NUT
(4 REQ'D - PROVIDED)
P/N 111577343890
FRAME
5/16" SCREWS OR BOLTS
(20 REQ'D - NOT FURNISHED)
10 1/4"
260mm
OPTIONAL FOR
ACCESS PANEL
3"
76mm
31 3/4"
806mm
25"
635mm
3"
76mm
8 5/8"
219mm
OPTIONAL FOR
ACCESS PANEL
37 1/2"
952mm
OPTIONAL BRACKET
FOR ACCESS PANEL
OPTIONAL BRACKET
FOR ACCESS PANEL
No Lead Two-Level SwirlFlo
®
Wall Mount, Barrier-Free
Drinking Fountain with EZH2O
®
Bottle Filling Station
Model EZWS-EDFPBM117K
INSTALLER NOTE:
THIS DRINKING FOUNTAIN IS FURNISHED
WITH A BUBBLER AND VALVE INCLUDING
ALL CONNECTING FITTINGS WHICH ARE
MANUFACTURED OF COMPLETELY LEAD
FREE MATERIAL. SHUTOFF VALVE (NOT
FURNISHED) TO ACCEPT 3/8” O.D. UNPLAT-
ED COPPER TUBE.
MOUNTING INSTRUCTIONS
Refer to rough-in for location of plumbing and
electrical sources. The support frame is to be
installed rst. Hang upper panel to hanger on
frame. Fountains are to be attached to panel
and wall frame. Water service lines, waste lines
and electrical are assembled as required. Per-
form a nal check for leaks and correct functions
of fountains and chiller. (For details see the
installation instructions.)
Installation requires trap to be installed in
wall. Trap and service stop not included.
WALL OPENING
IMPORTANT: It is necessary to create a wall
opening 37 ½” W x 31 ¾” H and 25” above the
oor line.
ELECTRICAL DATA
Electrical outlet, three (3) conductor grounded.
Locate within safe reach of power cord.
Job Name: ______________________________
Date: __________________ Qty. ____________
Contact Info (Name, Phone, Email): __________
________________________________________
________________________________________
Approval: _______________________________
FINISHED FLOOR
ROUGH-IN DIMENSIONS
1/4” O.D. TUBE
WATER INLET
TO COOLER
3/8” O.D. TUBE CONNECT
COLD WATER SUPPLY
BUILDING WATER
INLET
NOTE: WATERFLOW
DIRECTION
SERVICE STOP
(NOT FURNISHED)
RATED FOR INDOOR USE ONLY
B CA
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
A B C
FOR DRAIN CONNECTION
AND ACCESS TO
BOTTLE FILLER
ELECTRICALS
2222 Camden Court
Oak Brook, IL 60523
630-572-3192
elkay.com
WALL LAYOUT