Figure 4 - Upper Panel Installation
Figure 5 - Fountain Installation
15
22
28, 29, 30, 31, 32
19
23
23
View From Rear
5
22
17
8. Install reset switch for bottle ller (Fig 5). Connect the switch
wire to the extension wire on the back of the bottle ller. Wrap
up the excess cord.
9. Attach waste tubes (1-1/4” O.D.) to 1-1/4” O.D. slip trap.
Trap on the bottle ller side must be 1-1/2” O.D. (provided by
others).
10. Make nal water supply connections.
11. These products are designed to operate on 20-105 PSIG
supply line pressure. If inlet pressure is above 105 PSIG, a
pressure regulator must be installed in the supply line.
Caution: Any damage caused by connecting these products
to a supply line with pressure lower than 20 PSIG or higher
than 105 PSIG IS NOT covered under warranty.
12. Make electrical connections to the bottle ller and remote
chiller. The LCD Bottle counter should illiminate.
13. Verify proper dispensing from the bottle ller by placing a cup,
hand or any opaque object in front of sensor area and verify
water dispenses. Note: the rst initial dispenses might have air
in the line which may cause a sputter. This will be eliminated
once all air is purged from the line. A steady stream of water
assures all air is removed. The sensor has a 20 second maxi
mum ON time. It may be necessary to step away from the
beam a few times to purge all air. Check for leaks.
14. Check stream height from bubbler. Stream height is factory set
at 35 PSI. If supply pressure varies greatly from this, remove
push button (Item 7 - Figure 9) and adjust the screw on the
regulator (Item 8 - Figure 9). To remove push button, remove
setscrew from bottom of sleeve (Item 6). Insert a small punch
in screw hole and push up while grasping the push button and
pull forward removing the push button. Clockwise adjustment
will raise stream height and counterclockwise movement will
lower stream height. For best adjustment stream should hit
basin approximately 6-1/2” from the bubbler. Reassemble the
push button by pushing in on button until the push button
catches in the sleeve. Reinstall the setscrew (Item 24) in the
sleeve (Item 6).
15. Install the cover plates.
16. Install the bottom panel, tighten screws (Fig 4).
17. Optional: Mount optional panels. Slide tongue of panel under
edge of already installed panel. Tighten screws.