Specification Sheet

97924C (Rev. G - 2/12)
ERPB2-8C, ERPB2-8RAC, ERPBV2-8C, ERPBV2-8RAC, LRPB2-8C, LRPB2-8RAC, ERPB2-8C*2C, ERPB2-8C*3C
ERPB2-8GRNC*A, ERPB2-8GRNRAC*A, LRPB2-8GRNC*A, LRPB2-8GRNRAC*A
1
2
3
4
5
6
7
8
9
10A
10B
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
56073C
98502C
40319C
40608C
50171C
50314C
56011C
55997C
75580C
98118C
98481C
100322740560
15009C
55001132
55000944
45767C
28343C
45781C
45847C
45848C
50986C
61313C
15005C
56163C
45769C
45768C
56092C
70682C
55996C
28383C
28384C
28948C
28949C
27026C
111008343890
70432C
38417001
75560C
75632C
70817C
70020C
28395C
70683C
75671C
Bubbler Assy
Bubbler Assy (Stream Saver)
Fitting - Orifice
Fitting - Orifice (Stream Saver)
O-Ring
Orifice - Flow Straightener
Housing Assembly
Pedestal
Bubbler Locknut
Bubbler Assembly VR
Bubbler Assy. VR StreamSaver
Gasket - Black .68 x 1.03 VR
Nipple - Bubbler VR
Basin - Swirlflow
Lower Shell
Fountain Body
Cover Plate
Sleeve
Pin - Push Button
Push Button
Holder - Regulator
Regulator
Retaining Nut
Gasket - Drain
Assy - Drain/Tailpipe
Drain - Plug 1-1/2”
Poly Tubing (Cut To Length)
Tee - 1/4
Strainer (Provided with Chiller)
Back Panel RH ADA
Back Panel LH ADA
Back Panel RH ADA (Grn Spec)
Back Panel LH ADA (Grn Spec)
Lower Panel
Screw - #10-24 x .62 HHSM
Screw - #8-32 x .38 THSM
Screw - #8-18 x .37 HHSM
Screw - 5/16-18 x 1.00 HHMS
Setscrew - #10-32 x .38
Fttng - Elbow 1/4 x 1/4
Nut - Hex 5/16-18
Bracket - Support
Fitting - Union 1/4 x 1/4
Spring - Push Button
ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484
Page 8
Figure 12 – Water Supply Connections
Installation Package
The components for installation are packed in three
separate boxes, regardless of the type of unit being
installed. The boxes contain the following:
Box No. 1: Wall Frame(s)
Box No. 2: Remote Chiller, ECH8
Box No. 3: Fountain(s), Arm(s) and Panels
Additional materials, as noted in the Parts List, are also
shipped in these boxes.
PARTS LIST
ITEM NO.
PART NO.
DESCRIPTION
TROUBLESHOOTING & MAINTENANCE
Orifice Assembly: Mineral deposits on
orifice can cause water flow to spurt or not
regulate. Mineral deposits may be removed
from the orifice by poking with a small round
file not over 1/8” diameter, or using a small
diameter wire.
DO NOT file or cut orifice
material.
Stream Regulator: If orifice is clean,
regulate flow as in Step 11 of the installation
instructions. If replacement is necessary, see
parts list for correct regulator part number.
Actuation of Quick Connect Water
Fittings: Cooler is provided with lead-free
connectors which utilize an o-ring water seal.
To remove tubing from the fitting, relieve water
pressure, push in on the gray collar while
pulling on the tubing. (See Figure 13) To insert
tubing, push tube straight into fitting until it
reaches a positive stop (approximately 3/4”).
Figure 13 – Quick Connect Fittings
NOTE: WATER FLOW
DIRECTION
BUILDING WATER
INLET
SERVICE STOP
(NOT FURNISHED)
1/4" O.D. TUBE
WATER INLET
TO COOLER
3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY
REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620