Specification
44 9/16"
1132mm
49 3/4"
1264mm
18"
457mm
34 1/8"
867mm
16 3/4"
425mm
10"
254mm
23 7/8"
606mm
27"
686mm
15 1/4"
387mm
18 3/4"
476mm
7 1/8"
181mm
3"
76mm
3"
76mm
1"
25mm
3/4"
19mm
1 1/2"
38mm
3 1/4"
83mm
3"
76mm
4"
102mm
5 1/2"
140mm
F
C
B
E
E
B
A
G
D
FINISHED FLOOR
5/8"
16mm
31 1/4"
794mm
33 1/4"
845mm
H
ALTERNATE
ELECTRICAL
OUTLET
LOCATION
22 1/8"
561mm
Legacy Backsplash Style
Wall Mount Water Cooler
Models EHFSA8 & EHFSAD
REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER
RATED FOR INDOOR USE ONLY
Open space rough-in design permits new installation or replacement of existing
fountains and coolers with this Elkay cooler when rough-in is within the outline
shown.
IMPORTANT! INSTALLER PLEASE NOTE:
This water cooler has been designed and built to provide water to the user which
has not been altered by materials in the cooler waterways.
The grounding of electrical equipment such as telephone, computers, etc to water
lines is a common procedure. This grounding may be in the building or occur away
from the building. This grounding can cause electrical feedback into a water cooler
creating an electrolysis which creates a metallic taste or causes an increase in the
metal content of the water. This condition is avoidable by installing the cooler using
the proper materials as shown below.
NOTICE
This water cooler must be connected to the water supply using a dielectric coupling.
The cooler is furnished with a non-metallic strainer which meets this requirement.
The drain trap, which is provided by the installer, should also be plastic to com-
pletely isolate the cooler from the building plumbing system.
B CA
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
A B C
BUILDING WATER
INLET
SERVICE STOP
(NOT FURNISHED)
NOTE: WATERFLOW
DIRECTION
3/8” O.D. TUBE CONNECT
COLD WATER SUPPLY
1/4” O.D. TUBE
WATER INLET
TO COOLER
ROUGH-IN DIMENSIONS
Printed in U.S.A.
© 2014 Elkay
2222 Camden Court
Oak Brook, IL 60523
630-572-3192
elkay.com
Job Name: ____________________________________
Model: _______________________ Qty. ____________
Contact: ______________________________________
Approval Signature: _____________________________
Notes:
A = RECOMMENDED WATER SUPPLY LOCATION. SHUT OFF VALVE (NOT FURNISHED)
TO ACCEPT 3/8” O.D. UN
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN
C = 1-1/4 TRAP NOT FURNISHED**
D = ELECTRICAL OUTLET LOCATION
E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152mm) (MIN.) CLEARANCE
FROM CABINET LOUVERS TO
F = POWER CORD 1-1/2FEET (457mm) LONG
G = THIS BOLT HOLE MUST BE USED FOR FASTENING UNIT TO WALL.
H = ORIFICE HEIGHT 1-1/4” (32mm) ABOVE RIM