NOTE: WATERFLOW
DIRECTION
S
ERVICE STOP
(
NOT FURNISHED)
3
/8" O.D. TUBE CONNECT
C
OLD WATER SUPPLY
1/4" O.D. TUBE
WATER INLET
TO COOLER
BUILDING WATER
INLET
NOTE: WATERFLOW
DIRECTION
S
ERVICE STOP
(
NOT FURNISHED)
3
/8" O.D. TUBE CONNECT
C
OLD WATER SUPPLY
1/4" O.D. TUBE
WATER INLET
TO COOLER
BUILDING WATER
INLET
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
P
USHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
AB
C
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
P
USHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
AB
C
TANK DRAIN
4-5/8"
(117mm)
1-1/4" (32mm)
O.D. TAILPIECE
(TRAP NOT 
FURNISHED)
14-1/2"
(368mm)
18"
(457mm)
5"
(127mm)
4-1/4"
(108mm)
2-1/2" (64mm)
OPTIONAL
ELECTRICAL OUTLET
(BY OTHERS)
NOTE: INSURE PROPER VENTILATION BY MAINTAINING
4" (102mm) MINIMUM CLEARANCE FROM CABINET
LOUVERS TO WALL ON EACH SIDE OF COOLER.
4 FOOT (1.2mm) LONG
POWER CORD
14-1/2"
(368mm)
C
L
FLOOR LINE
WATER OUTLET
1-1/4" (32mm) I.P.S.
41-1/2"
(1054mm)
40"
(1016mm)
17"
(432mm)
ELECTRICAL OUTLET
LOCATION (BY OTHERS)
1-1/4" (32mm) O.D. TAILPIECE
3/8" IPS COLD WATER
SUPPLY (STUB OUT
FROM WALL 1" [25mm])
WATER INLET SHUTOFF
VALVE BY OTHERS
(3/8" O.D. TUBE OUTLET)
PLUMBING ROUGH-IN CAN
BE LOCATED ANYWHERE
WITHIN THIS AREA.
TANK DRAIN
4-5/8"
(117mm)
1-1/4" (32mm)
O.D. TAILPIECE
(TRAP NOT 
FURNISHED)
14-1/2"
(368mm)
18"
(457mm)
5"
(127mm)
4-1/4"
(108mm)
2-1/2" (64mm)
OPTIONAL
ELECTRICAL OUTLET
(BY OTHERS)
NOTE: INSURE PROPER VENTILATION BY MAINTAINING
4" (102mm) MINIMUM CLEARANCE FROM CABINET
LOUVERS TO WALL ON EACH SIDE OF COOLER.
4 FOOT (1.2mm) LONG
POWER CORD
14-1/2"
(368mm)
C
L
FLOOR LINE
WATER OUTLET
1-1/4" (32mm) I.P.S.
41-1/2"
(1054mm)
40"
(1016mm)
17"
(432mm)
ELECTRICAL OUTLET
LOCATION (BY OTHERS)
1-1/4" (32mm) O.D. TAILPIECE
3/8" IPS COLD WATER
SUPPLY (STUB OUT
FROM WALL 1" [25mm])
WATER INLET SHUTOFF
VALVE BY OTHERS
(3/8" O.D. TUBE OUTLET)
PLUMBING ROUGH-IN CAN
BE LOCATED ANYWHERE
WITHIN THIS AREA.
I
MPORTANT!
I
NSTALLER PLEASE NOTE:
This water cooler has been designed and built to provide water to the user which has
not been altered by materials in the cooler waterways.
The grounding of electrical equipment such as telephone, computers, etc., to water
lines is a common procedure. This grounding may be in the building but may also
occur away from the building. This grounding can cause electrical feedback into a
water cooler creating an electrolysis which creates a metallic taste or causes an
increase in the metal content of the water. This condition is avoidable by installing the
cooler using the proper materials as shown below.
N
OTICE
T
his water cooler must be connected to the water supply using a dielectric coupling.
T
he cooler is furnished with a non-metallic strainer which meets this requirement.
T
he drain trap which is provided by the installer should also be plastic to completely
i
solate the cooler from the building plumbing system.
No Lead Floor Model Water Cooler
Air Cooled
Models EFA4, EFA8, EFA14, EFA16 and EFA20
®
ROUGH-IN DIMENSIONS
Elkay
2222 Camden Court
Oak Brook, IL 60523
elkayusa.com
Printed in U.S.A.
©2011 Elkay
9-2I (Rev. 4/11)