7.4 Change the Range Of The IR Sensor
1. Depress the program button when the display reads
RNG SET.
2. The display will show the default RNG = 3. 1-10 is the
range, 1 is closest to the sensor, 10 is farthest away.
3. Depress the button again to change the value. When
the desired range is selected, wait four seconds for the
unit to default back to run mode.
4. Test the bottle ller by placing a hand or a bottle in front
of the sensor.
7.5 Change the Unit Type
1. Depress the program button when the display reads
UNIT TYP.
2. The display will show the default REFRIG.
3. Depress button to change to refrigerated if NON-
REFRIG is displayed.
4. When the desired range is selected, wait four seconds
for the unit to default back to run mode.
5. Test the bottle ller by placing a hand or a bottle in front
of the sensor.
7.6 Change Filter Capacity (Filtered Unit Only)
1. Depress the program button when the display reads
FLT SIZE.
2. The display will show the default 3000GAL.
3. Depress the button again to change the value to
6000GAL.
4. When the desired range is selected, wait four seconds
for the unit to default back to run mode.
7.7 Resetting the Bottle Count
1. Depress the program button when the display reads
RST BCNT.
2. The display will show the current value, e.g. 0033183.
3. Depress the button again to change the value to 0.
The display will show BTLCT = 0 for approximately 2
seconds and return to run mode showing 0000000 on
the display board.
Note: Once the bottle count is reset to 0, there is no way
to return to the previous count.
4. Test the bottle filler by placing a hand or a bottle in
front of the sensor and dispense product until the bottle
count changes to 1.