Installation Sheet

DSSBF8S
(630) 574-8484 Elkay Manufacturing Company
2000000216 (Rev. B - 08/21)
Page 11
6. Startup
1. Make sure that there are no leaks on the drain
connections and installed as per local regulations.
2. Plug-in the water cooler unit.
3. Once power is applied to the bottle ller, the GREEN
LED light will illuminate showing good lter status
along with the LCD Bottle Counter.
4. Verify proper dispensing by placing cup or any object in
front of sensor area and verify water dispenses.
Note: The first initial dispenses might have air in line which
may cause a sputter. This will be eliminated once all
air is purged from the line.
5. Check all the lines and connections for water leaks.
Repair connections if necessary.
6. Dispense at least two gallons of water to bleed o󰀨 any
trapped air from supply lines and ne carbon particles
from the lter. If there are no leaks and unit is
functioning correctly, re-install the front cover by
installing the two hex screws on the bottom side of the
cooler using a 5/16" socket or nut driver.
7. Upon initial startup, the plastic bottles saved indicator
panel should show several bottles saved due to the
water used to initially start up of the unit.
GREEN: 0 - 80% of Filter Life or 0 - 11
Months.
YELLOW: 80 - 100% of Filter Life or 11 - 12
Months (Whichever Comes First).
RED: 100% Plus of Filter Life or 12
Months (Whichever Comes First).
7. Changing the Factory Default
Settings (Not Required for
Installation)
7.1 Accessing the Programming Button
1. Remove the bottle ller top cover by removing the four
phillips screws using a phillips screwdriver. Do not
discard the screws, they are required for re-assembly.
2. Locate the programming button at the top right side of
the unit on the control board.
7.2 Access the Programming Menu
1. Depress the program button for approximately two
seconds until the display changes, then release.
2. The display will scroll through two messages.
a. RST FLTR – Reset Filter Monitor (ltered units
only).
b. SETTINGS – System Setting Sub Menu.
Depress the program button when the display reads
SETTINGS. The display will scroll through four
messages:
RNG SET – Range set for IR sensor. Default is 3.
UNIT TYP – Type of unit. Default is refrigerated.
FLT SIZE – Select lter capacity. Default is 3000 GAL.
RST BCNT – Reset bottle count (ltered units only).
3. Push the button while the desired message is
displayed. If the program button is not pushed, the
messages will cycle three times before resetting back
to run mode.
7.3 Reset the Filter Monitor (Filtered Unit Only)
1. Depress the program button when the display reads
RST FLTR.
2. Depress the program button when the display reads
FLTR = and the display will change to FLTR = 0.
3. The green LED on the bottle ller panel should now be
illuminated indicating that the lter monitor has been
reset.
Lower Front
Panel