Installation Sheet
20
Carbonaon Chiller, Fontemagna Bridge and Column Tap
Installaon and Maintenance Manual
Twice a Year
Replace the water lter aer 6000 gallons or 6 months, or earlier depending on water quality.
NOTICE: The lter head has an internal shuto valve that stops the ow of water when the lter is
removed. It is not necessary to shut o the water supply.
1. Turn used lter counterclockwise (to the le) 1/4 turn to remove from lter head. Pull lter away from head
and remove.
2. Remove the cap from the new lter. Place the cap on the used lter to seal it.
3. Insert the new lter into the lter head and turn the lter clockwise (to the right) unl it stops.
4. Place a receptacle under the sll water dispenser and dispense connuously for a minimum of two gallons to
purge air and ne carbon parcles from lter.
Sanize the machine
NOTICE: This operaon must be carried out by your ELKAY reseller or by a qualied technician
When required
Replace the UV lamp (Fontemagna Bridge only)
CAUTION: The light emied by the ultra-violet lamp
may cause serious burns to the eyes and skin.
Disconnect the electrical source of supply of the UV
radiaon before opening the machine.
1. Disconnect the unit from its electrical source.
2. Once the unit is shut down, unscrew the lower screws of
the dispensing head (A). Rotate backward the aluminum
cover unl you have access to the superior dispensing
area.
3. Loosen the screws of each dispensing valve in order to remove the UV lamps from their dedicated slot.
Disconnect the electrical connector of the UV OUT lamp. Pull the lamp removing it from its ng holder —
handling it carefully.
4. Insert the new lamp and reconnect the connector — handling it carefully.
5. Repeat the procedure for all the dispensing valves.
6. The used UV lamps can be disposed at your local waste management site.
A