Installation Sheet
15
1000002475 (Rev. D - 04/2016)
9. Purge the water lines.
1. Place receptacle beneath tap to catch dispensed water. Discard water as necessary.
2. Allow water to run connuously unl ow is clear of air.
3. Repeat for all taps.
NOTICE: On the Column Tap, use the lever (A) to regulate the water ow: rotate counterclockwise to
increase the ow or rotate clockwise to decrease it.
10. Open the CO
2
valve.
4. Using a screwdriver slowly turn valve screw counterclockwise (le)
to open valve.
5. Connue unl pressure reads 55 psi to 60 psi max.
11. Re-purge the line for sparkling water.
NOTICE: The water will ow at at rst, then gradually
become more sparkling as the line is purged of sll water.
12. Allow machine to complete inial chilldown.
NOTICE: Complete chilling of ice bank will require 1-3 hours. The machine should not be used as a water
dispenser unl chilling is complete.
Open both
taps
Press and hold
dispensing buon
Fontemagna Bridge Column Tap