Carbonaon Chiller, Fontemagna Bridge and Column Tap
Installaon and Maintenance Manual
2. Cut, size and connect water and CO
2
piping to t your installaon.
NOTICE: The water pressure entering the machine must be between 14.5 psi (0.10 MPa) minimum and
51 psi (0.35 MPa) maximum.
NOTICE: An incoming ow rate of >1.0 gallon/minute is recommended for opmal quality of sparkling
water.
NOTICE: Check all input piping and connecons for leaks before connecng to the machine.
Water source:
threaded
ng
Water
source: open
3/8" pipe
Water lter
3/8" quick
connect
adapter
3/8" quick
connect
adapter
Water
shuto
valve
Water pressure
regulator
Water
piping cut
to size
Water piping
cut to size
To water
cooler
Short
3/8"– 3/8" pipe
Using the quick connect ngs
To connect:
1. Make clean, 90° cut to
piping end.
2. Push piping straight into
ng unl it stops.
3. Pull back to check that
connecon is secture.
To disconnect:
1. Press in the end tab.
2. Pull piping out.
3. Release tab.
1/4” Gas tubing
cut to size
Regulator
CO
2
source
3/8’’ x 3/8’’
quick connect
3/8’’ x 1/4’’
quick connect
connector
1/4’’ tubing
4’’ long
3/8’’ water
tubing cut
to size
Recommended total
lenght 6 feet
Use one of two
connecon
methods