Installation and Maintenance Manual COLUMN TAP Table of Contents Declaration of Conformity Association Recommendations for Safeguarding the Environment Explanation of Warning/Safety Icons Introduction Components Guide Product Specifications 2 2 3 3 4 5 6 Before You Begin – Requirements for Installation Mounting Dimensions Operating Environment Water Electrical Tools You Will Need Unpacking the Kit What’s in the Kit 7 7 8 8 8 9 9 10 Installing the Water Cooler and the Supply head Operating the Touch Con
Carbonation Chiller, Fontemagna Bridge and Column Tap Installation and Maintenance Manual Declaration of Conformity D.M. 174 Materials compliant for contact with drinking water TA LY C NI 10 0 % M AD E T I F I C AT E ER I This unit is intended for the dispensing of drinking water, and so the materials that enter into direct contact with water meet the criteria for food-grade components pursuant to the current legislation.
ITPI rosso 032 c I TA LY C 10 IN T I F I C AT E ER 0 % M AD E D.M. 174 ITPI rosso 032 c Recommendations for Safeguarding the Environment Packaging materials The packaging materials are 100% recyclable. Please follow the local guidelines on waste disposal. For safety reasons keep the packaging material out of the reach and sight of children. Scrappage The Carbonation Chiller water cooler, Fontemagna Bridge and Column Tap supply head are made using recyclable material.
Carbonation Chiller, Fontemagna Bridge and Column Tap Installation and Maintenance Manual Introduction The Carbonation Chiller water cooler, Fontemagna Bridge and Column Tap supply head bring contemporary style and state-of-the-art technology to commercial water dispensers. Carbonation Chiller undercounter water cooler can be used with either Fontemagna Bridge or Column Tap, combining professional performances with a modern, sleek design.
Components Guide Carbonation Chiller Sparkling water outlet Fontemagna Bridge Column Tap Room temperture water outlet Compensator Cold water outlet Power button Sparkling water nozzle Touch Control keypad Thermostat Cold water nozzle Ice bank inlet CO2 inlet Drip tray Ice bank overflow Water inlet Ice bank level Sparkling water inlet Cold water inlet Room temperture water inlet Cold water inlet Power cable Sparkling water inlet Power cable Dispensing buttons – small serving large serving
Carbonation Chiller, Fontemagna Bridge and Column Tap Installation and Maintenance Manual Product Specifications Specification Carbonation Chiller Fontemagna Bridge Column Tap ø 3/8" ø 3/8" ø 3/8” Supply 115V - 60Hz (230V - 50Hz) 115V - 60Hz (230V - 50Hz) Power 330W - 3.2A 50W - 0.44 A Min 41°F – Max 107.6°F (Min 5°C – Max 42°C) Min 41°F – Max 107.6°F (Min 5°C – Max 42°C) UNIT WEIGHT lb (kg) 59 (27) 33 (15) 9 (4) SHIPPING WEIGHT lb (kg) 66 (30) 35 (16) 11 (5) 12.5 x 18.4 x 18.
Before You Begin – Requirements for Installation Mounting Dimensions (Carbonation Chiller only) Under counter (includes 4" clearance on sides and back) Width 20.5"(520mm) Depth 24.6" (625mm) Height 26.6" (675mm) Footprint: 12.5" x 18.4" 317mm x 467mm Depth 3.88" (99mm) Width 3.25" (83mm) Height: 28" (711mm) Height: 12.75" (324mm) Diameter 8" (203mm) Water filter CO2 cylinder (typical, 20 pound) 1000002475 (Rev.
Carbonation Chiller, Fontemagna Bridge and Column Tap Installation and Maintenance Manual Operating Environment OO OO Install the machine in a clean, dry, well-ventilated room. It is designed to function correctly in environments with a temperature of 16°C to 32°C – Climatic Class N, (between 61°F and 90°F). Check that the water cooler is level, that it is on a surface that can support its weight and in an environment suitable for its size and use. OO Do not place the machine near a source of heat.
Tools You Will Need (2) 8" adjustable wrenches (1) 10" adjustable pliers (1) 12" adjustable wrench (1) 12" pipe cutter (1) electrical drill (1) 0.39’’ drill (1) universal screwdriver (1) wire cutting pliers (1) 1.57’’ drill Unpacking the Kit Remove the front panel (labeled FRONT) and cover of the wooden packing case. Remove the cardboard box and the internal protective packaging by sliding them up and over the top.
Carbonation Chiller, Fontemagna Bridge and Column Tap Installation and Maintenance Manual What’s in the Kit (3) 10' coil water tubing 3/8” O.D. (blue) and (3) 10’ coils of tubing insulation (not snown) (1) CO2 regulator (1) supply hose 1/2 ips x 3/8 tube x 12” long PLUS (2) 3/8" – quick connect connector or (1) 10' coil CO2 tubing 1/4” OD (natural) 3.94 [ ] ] ] 1.57 [ ] [ 3.94 ] [ 1.5 ] 0.33 [ ] 7 ] 9 1.38 [ ] ] 1.5 0.3 [ [ B 3.
Installing the Water Cooler and the Supply Head CAUTION: Wear safety gloves when handling the machine. Metal edges are sharp, and touching them could result in minor or moderate injury. CAUTION: Water cooler weighs more than 100 lbs (45 kg) when the ice bank is filled. Lifting without proper support could result in minor or moderate injury. 1. Install external water filter and CO2 cylinder. 1. Use (2) Phillips head screws to mount bracket to under-counter wall. 2.
Carbonation Chiller, Fontemagna Bridge and Column Tap Installation and Maintenance Manual 2. Cut, size and connect water and CO2 piping to fit your installation. NOTICE: The water pressure entering the machine must be between 14.5 psi (0.10 MPa) minimum and 51 psi (0.35 MPa) maximum. NOTICE: An incoming flow rate of >1.0 gallon/minute is recommended for optimal quality of sparkling water. NOTICE: Check all input piping and connections for leaks before connecting to the machine.
3. Fill the ice bank in your water cooler. 1. Insert piping from water supply (A) into ice bank 3/8” inlet quick connect on the front side on the machine (B). 2. Fill slowly until water reaches the maximum fill line on the overflow tube on the back side of the machine (C). 3. If water exceeds this level, water will flow from overflow (D). Carbonation Chiller D 4. If you have to move the unit, remember to empty the ice bank first. 5. Turn off water supply and remove piping from ice bank inlet. 4.
Carbonation Chiller, Fontemagna Bridge and Column Tap Installation and Maintenance Manual 6. Place the supply head on the counter top. Fontemagna Bridge Column Tap 1. Use the template provided in the kit to drill the mounting holes on the counter top. 1. Place the valves and fully tighten the ring nuts. Screw in the knobs on the taps. 2.
9. Purge the water lines. 1. Place receptacle beneath tap to catch dispensed water. Discard water as necessary. Fontemagna Bridge Press and hold dispensing button Column Tap Open both taps 2. Allow water to run continuously until flow is clear of air. 3. Repeat for all taps. NOTICE: On the Column Tap, use the lever (A) to regulate the water flow: rotate counterclockwise to increase the flow or rotate clockwise to decrease it. 10. Open the CO2 valve. 4.
Carbonation Chiller, Fontemagna Bridge and Column Tap Installation and Maintenance Manual Operating the Touch Control Keypad Fontemagna Bridge Only POWER H2O CO2 H2O H2O STOP CO2 CO2 MESSAGE STOP STOP To turn on the machine H2O SPARKLING ROOM TEMPERATURE COLD SPARKLING SPARKLING ROOM TEMPERATURE ROOM TEMPERATURE COLD COLD POWER POWER Note: The power button and dispensing button LEDs turn on.
To turn on Key Lock POWER H2O Press and hold the Energy Saving button for more than 4 seconds, until the machine beeps once. CO2 SPARKLING ROOM TEMPERATURE POWER H2O CO2 SPARKLING COLD STOP ENERGY SAVING Note: All of the button LEDs flash. MESSAGE ROOM TEMPERATURE COLD STOP ENERGY SAVING MESSAGE NOTICE: Key lock deactivates all the buttons on the POWER keypad. It should be activated before the keypad is cleaned.
Carbonation Chiller, Fontemagna Bridge and Column Tap Installation and Maintenance Manual Programming the Touch Control Keypad Fontemagna Bridge Only POWER POWER By default, the Fontemagna Bridge dispenses a single 7 oz (0.2 liter) serving when the upper dispensing button is pressed, and a 34 oz (1 liter) serving when the lower dispensing button is pressed. You can change the default serving size by entering Programming Mode.
Routine Maintenance Daily OO Clean all external surfaces of the machine, the drip tray and the dispensing nozzles. NOTICE: It is recommended that all external components of the product be cleaned daily. It is recommended that you use dish soap, warm water and a clean, soft cloth to clean the product. DO NOT USE THE FOLLOWING PRODUCTS: Do not use ... chlorine bleach solutions on the product. Chlorides found in most soaps, detergents, bleaches and cleaners can attack stainless steel.
Carbonation Chiller, Fontemagna Bridge and Column Tap Installation and Maintenance Manual Twice a Year OO Replace the water filter after 6000 gallons or 6 months, or earlier depending on water quality. NOTICE: The filter head has an internal shutoff valve that stops the flow of water when the filter is removed. It is not necessary to shut off the water supply. 1. Turn used filter counterclockwise (to the left) 1/4 turn to remove from filter head. Pull filter away from head and remove. 2.
NOTICE: This operation must be carried out by your ELKAY reseller or by a qualified technician. NOTICE: For the OO replacement of UV OUT pipe is not necessary to turn water off. Set the thermostat (Carbonation Chiller only) COLDER 1. Set the thermostat between 5 and 6 to control the temperature of the ice bank. 2. If you want to avoid the formation of ice in the bank, turn the thermostat screw located on the back side of the machine at least 1/4 anti-clockwise. 1 2 3 OFF 4 7 6 5 1000002475 (Rev.
Carbonation Chiller, Fontemagna Bridge and Column Tap Installation and Maintenance Manual Troubleshooting Problem No water dispense Problem Low flow dispense Problem Sparkling water doesn’t come out Problem Water is not cold enough 22 Possible Cause Action To Take The main water valve is closed Open the valve The power switch is set to OFF Set the power switch to ON Malfunction in the ribbon cable connection/ spade connectors (Compact and Bridge only) Repair connection to main circuit board Th
Problem Poor sparkling water quality Problem Volumetric is not working Problem Yellow (no CO2) alarm on Problem Red (no water) alarm on Problem Dripping water Possible Cause Action To Take Incorrect air gap in the carbonator Close the CO2 cylinder valve, pull up the ring on safety valve (on the carbonator bowl head) until all air gap is out Use of rinse aid or highly polished glass Avoid excessive use of rinse aid The CO2 regulator is set low Set the CO2 regulator between 55-60 psi (3.
Carbonation Chiller, Fontemagna Bridge and Column Tap Installation and Maintenance Manual Problem Noise/Vibration Possible Cause The ice bank is empty Fill the ice bank The agitator or the pump is not covered by water Fill the ice bank The copper tubing is vibrating against the cabinet Fix the position of the the tubing The fan is dirty Clean or replace it Contacting Customer Support Elkay Manufacturing Company 2222 Camden Court Oak Brook, IL 60523 800.416.
Fontemagna Compact DSFCF180UVK Blubar Countertop DSBCF180K Description X X 1000002622 Motor Fan 120x120x25 Motor Fan for the Carbonation Chiller, Fontemagna Compact, and Blubar Countertop models X X X 1000002623 Booster Pump Booster Pump for the Carbonation Chiller, Fontemagna Compact, and Blubar Countertop models X 1000002624 Level Control Level Control for the Carbonation Chiller and Blubar Countertop models X Fontemagna Bridge DSFB1UVK Carbonation Chiller DSFBF180K Product Name X P