Installation Sheet
PAGE 5 98421C (Rev. C - 09/17)
HDFF-EBPFR*A HDFF-BLEBPFR*A HDFF-BLREBPFR*A
HDF-EBP-FR WITH MP101 MUNTING PLATE
ROUGH-IN DRAWINGS
FIG. 4
1. Wall should already be framed for the fountain using dimensions shown in Fig. 1. Shown dimensions pertain to installation location.
These dimensions are required for compliance with ANSI Standard A117.1. and ADA (Framing shown for reference only).
2. Remove bottom cover from fountain and save the screws.
3. Install the fountain using bolts and washers (provided). Tighten securely.
4. Attach drain tube to fountain and cut to required length using the freeze resistant box as a guide.
5. Install freeze-resistant box - see box instructions.
6. Replace bottom cover.
13"
330mm
28 9/16"
725mm
27"
686mm
ADA
REQUIREMENT
6 1/2"
165mm
3 13/16"
97mm
12 1/8"
308mm
19 3/4"
502mm
20 3/8"
518mm
5/8"
16mm
18"
457mm
14"
355mm
17 1/2"
444mm
2 5/8"
66mm
3 5/8"
91mm
12"
305mm
MAX. WALL
THICKNESS
FINISHED FLOOR
FINISHED WALL
MPW101 MTG. PLT.
REF. SEPARATE
INSTALLATION
INSTRUCTIONS
FOR DETAILS