DESCRIPTION
45835C
75617C
75616C
70204C
75611C
70421C
1
2
3
4
5
6
PART NO.
Adapter - Direct Bury Fountain
ROD -3/4" DIA (UNPAINTED)
Nut - 3/4" - 10UNC-2B Hex.
Bolt - 3/8"-16UNC-2A Hex. Hd.
Washer - 3/8" Lock
Washer - 3/8" Plain
ITEM NO.
PARTS LIST
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.260.6640
PRINTED IN U.S.A.
FOUNTAIN BODY
1
2, 3
4, 5, 6
FINISHED GRADE
CONCRETE
INSTALLATION INSTRUCTIONS
1. Thread Nuts (Item 3) onto Rods (Item 2)(one Nut per Rod).
2. Thread Rods into Adapter Cylinder (Item 1) and tighten Nuts
against Cylinder Securely.
3. Place Washers (Item 6) on Bolts (Item 4)(one Washer per
Bolt), Assemble Bolts into Adapter Flange. Thread Bolts
all the way in.
4. Secure Adapter into Concrete Forms as per Standard
Practice and as Shown Below. Be sure to Align Adapter
for proper location of Water Inlet Line, Drain Line, and
required Fountain Alignment.
5. After Sufficient Cure of Concrete, remove Flange Bolts and
Washers.
6. Mount Fountain Assembly per Instructions Supplied with
Fountain and Items 4, 5, & 6 (See Below).