Performance Data Sheet

97976C (Rev. L - 06/16)
The ELKAY Aqua Sentry lter has been tested according to NSF/ANSI 42 and 53 for reduction
of the substances listed below. The concentration of the indicated substance in water entering
the system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as specied in NSF/ANSI 42 and 53.
FOR REPLACEMENT FILTER, PLEASE CALL 1.800.22ELKAY
ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484
PRINTED IN U.S.A.
Order Replacement Filter 56192C
Recommendation: Filter to be replaced every 6 months or when
changes in taste, odor, color and/or ow of the water occurs.
Testing was performed under standard laboratory conditions, actual performance may vary.
Substance
Inuent Challenge
Concentration
Maximum
Permissible
Product Water
Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
NSF / ANSI Standard 42
Aesthetic Effects
Chlorine Taste & Odor 2.0 mg/L ± 10% ≥ 50% 94.8% 97.4%
Particulates
(0.5-<1m)-Class 1
at least 10,000
particles/mL
≥ 85% 99.5% 99.8%
NSF / ANSI Standard 53
Health Effects
Cysts Minimum 50,000/L 99.95% 99.95% 99.9%
Lead (pH 6.5) 0.15 mg/L ± 10% 0.010 mg/L 99.3% 99.3%
Lead (pH 8.5) 0.15 mg/L ± 10% 0.010 mg/L 96.6% 96.9%
Atrazine 0.009 mg/L ± 10% 0.003 mg/L 83.2% 91.7%
Lindane 0.002 mg/L ± 10% 0.0002 mg/L 94.5% 98.2%
Test Conditions
Flow Rate = as noted for lter system
Inlet Pressure = 60 psi (4.1 bar)
pH 7.5 ± 1
Temperature = 68°F ± 5°F (20°C ± 2.5°C)
Operating Requirements
Pressure = 20-100 psi (1.4-6.89 bar)
Temperature = 35° - 100°F (2° - 37.8°C)
Turbidity = 5 NTU Max.