Installation

Page 1 98525C (Rev. K - 06/19)
NOTE: This system and installation shall comply with applicable
state and local regulations.
FILTER KIT
HWF3000 WaterSentry
®
Plus Kit
(Lead, Chlorine, Taste & Odor, and Particulate Class I Reduction)
FOR COMMERCIAL USE ONLY
These lter kits are designed to be used with the following
Halsey Taylor products.
Halsey Taylor
®
HydroBoost
®
Bottle Filling Station Models
Examples include but not limited to: HTHB*
NOTICE: Do not use with water that is microbiologically
unsafe or of unknown quality without adequate
disinfection before or after the system. Filter
mustbeusedwithltermonitorfor3000
gallon rating
General Installation Instructions
1. Theselterkitsmust be installed in compliance with all
state and local laws and regulations governing the
installation and use of this product. Maximum inlet
water temperature 100°F (38°C).
2. Mountlterhead in a suitable location, using the lter
mounting bracket and screws supplied. Allow enough
room under the lter head for installation and removal of
lter cartridge (13" minimum).
3. Connect the cold water supply to the lter through a
shut-off valve and 3/8" O.D. tubing (supplied by the
installer). For ease of servicing, the shut-off valve
should be located within easy reach of the lter.
NOTE:Theinletandoutletttingsuppliedas
partofthelterheadareJohnGuestSuperseal
ttingsthataccept3/8"O.D.tubingonthelter
inletand1/4"O.D.tubingontheoutlet.Theymay
be used with copper, semirigid nylon or polypropylene
tubing, with a rated working pressure equal or greater
than encountered in application. Do not use soft or
braided tubing.
4. CAUTION: If supply pressure will ever exceed
100 psi, install a pressure regulator to limit the
inletpressuretothelterto100psiorbelow.
DONOTATTACHHOTWATERLINETOFILTER.
To make connections on the lter head, loosen locknut.
Push the tube end past both o-rings to a positive stop in
the lter head recess - approx. 1", locknut may have to
be backed out a little more. Screw the locknut hand tight
to seal (See Fig. 1). Ends of tubing must be cut square
and free of burrs and sharp ends that could cut or nick
the o-rings.
5. Connect the outlet of the lter to the inlet of the union
using the 1/4" O.D. poly tubing and 1/4" union supplied.
6. Removelterfromcarton, remove protective cap, attach
lter to lter head by rmly inserting into head and
rotating lter clockwise.
B CA
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
A B C
WaterSentry Plus In-Wall Bottle Filler and Water Cooler
7a. Turn on water supply and hold open the bubbler on cooler
until approximately 1 gallon of water is dispensed.This ushing
procedure purges air and ne carbon particles from the lter.
When 1 gallon of water has been purged through the cooler,
carefully inspect all water connections for leaks.
FIG. 2
FIG. 1
SeeNote4:Screwthelocknuthandtighttoseal
Filter Replacement
1. Turn inlet water valve off.
2. Open bubbler or activate the electric eye to relieve pressure
build-up in the system.
3.Removeusedlter from head by rotating lter counterclockwise.
4.Removenewlter from carton, remove protective cap; cap may
be placed on old lter to reduce the chance of water spilling from
lter housing.
5.Attachlterto lter head by rmly inserting into head and
rotating lter clockwise.
NOTE:Thelterheadcontainsanautomaticshut-offvalvethat
stops the ow of water, if the lter is removed inadvertently
without shutting off the incoming water.
WaterSentry Plus In-Wall Bottle Filler
7b .Turn on water supply and activate the electric eye on In-Wall
Bottle Filler until approximately 1 gallon of water is dispensed.
Please note that the electric eye activation times out at 30
seconds and will need to be activate repeatedly until one gallon
has been passed. This ushing procedure purges air and ne
carbon particles from the lter. When 1 gallon of water has
been purged through the bottle ller, carefully inspect all water
connections forleaks.
®
(NOTE:CTOreplacementlterisonlycertiedtoNSF42claims;seeWSF6000RPerformanceDataSheet
for additional information.)
®
IMPORTANT NOTE - To avoid danger of an electric shock hazard, disconnect power to
yourunitbeforeinstallingorreplacingthelter.
The WaterSentry
®
Plus lter is tested and certied by NSF International to NSF/ANSI 42 and 53 for
the reduction of Chlorine, Taste and Odor, Particulate Class I, and Lead.

Summary of content (4 pages)