Performance Sheet
For replacement filters, please call 800.834.4816
1333 Butterfield Road, Suite 200 | Downers Grove, IL 60515
630.574.8484 | elkay.com | ©2021 Elkay Manufacturing Company
Document 2000000234
F-6074-ELK
Elkay
®
WaterSentry
®
Plus
Manual & Performance Data Sheet
IMPORTANT NOTICE: Read this Performance Data Sheet and compare the capabilities of this unit with your actual
water treatment needs. It is recommended that, before purchasing a water treatment unit, you have your water supply
tested to determine your actual water treatment needs.
CAUTION: For use on cold water line only. Do not allow installed filter to freeze.
RECOMMENDED USE CONDITIONS
System Model
Replacement Element
Working Pressure
Operating Temperature
Flow Rate
Capacity
EWF3000 51300C
20 – 105 psi
(241 – 724 kPa)
(1.4 – 7.4 Kg/cm
2
)
40 – 100° F
(5 – 38° C)
1.5 GPM
(5.7 L/min)
3,000 gal
(11,356 L)
1 Year Maximum
This system has been certified by IAPMO R&T and tested according to NSF/ANSI 42 and 53 for the reduction of the
substances listed below. The concentration of the indicated substances in water entering the system was reduced to a
concentration less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI 42 and 53.
Contaminant
Influent Challenge
Concentration
Maximum Permissible Product
Water Concentration
Particulate, Class I
At least 10,000 particles/mL*
≥ 85% reduction
Chlorine, Taste and Odor
2.0 mg/L ± 10%
≥ 50% reduction
Lead
†
0.15 mg/L ± 10%
0.005 mg/L
Cysts
Minimum 50,000/L
≥ 99.95% reduction
*Particulate, Class I size: 0.5 to < 1µm
†
Soluble and particulate lead
Not all water will contain contaminants listed. Performance will vary depending on local water conditions. While testing
was performed under standard laboratory conditions, actual performance may vary. Do not use with water that is
microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified
for cyst reduction may be used on disinfected waters that may contain filterable cysts. Filter installation and usage must
comply with applicable local and state regulations.