Installation
Page 5 1000005920 (Rev. A - 09/20)
1000005921
20. Place the basin shroud assembly back on to the cooler frame and
connect the sensor wires by plugging the connector from the sensor to
the connector on the power cord. At this time also connect the water line
to the solenoid. See Fig.10.
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816
REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640
PRINTED IN U.S.A.
21. Place the (4) screws back in to hold the basin/shroud assembly to the frame.
22. Reconnect the drain lines.
23. Remove the plastic covering the sensor bar.
24. Turn on the water and plug the cooler back in. Place a cup over the bubbler and activate the sensor. Run water until all air is removed from the
system and there is a steady stream of water coming from the bubbler.
25. Check for any water leaks and x as needed.
26. Place the lower wrapper on the cooler and tighten the (4) screws.
Fig. 10