Installation

Page 21000005920 (Rev. A - 09/20)
1000005921
Note: These instructions are for converting a non-refrigerated EZ model cooler to Hands-free.
1. Remove Lower wrapper on the cooler by removing the (4) screws using a 5/16 nut driver
2. Shut o󰀨 water to the cooler
3. Remove water pressure by pressing on any of the cooler push bars until no water comes out of the bubbler
4. Unplug the water cooler
5. Remove the P-trap from the cooler drain
6. Remove the (4) screws – 2 per side on the upper shroud using the Torx
bit or Allen Wrench. See Fig.1.
7. Lift the basin shroud assembly, tilting forward towards the front of the water cooler. Take a black marker and mark the water line where it enters the
solenoid. This will ensure the water line is reinserted fully later. Remove the water line from the solenoid and unplug the two switch wires. One on
the solenoid and one on the power cord. Once both wires are free lift the assembly completely o󰀨.
8. Turn the basin/shroud assembly over on a table so that it is sitting on the basin.
9. If this is a single, non-refrigerated cooler locate the serial number on the data label and write it down in permanent marker on the blank label on
the bottom of the new shroud. If this is the non-refrigerated side of a two-level cooler the serial number will be on the refrigerated cooler and can
remain there.
10. Remove the basin from the shroud by removing the four screws with the Torx bit of Allen Wrench. Note if your shroud has a regulator installed
it will need to be removed too.
11. Remove the rubber boot with the drain by sliding up o󰀨 the three pins holding it to the shroud. Place the boot and drain on the three pins on the
new shroud. Press completely down so it is sitting at. See Fig.2 and Fig.3.
Fig. 1