Installation

Page 5 1000005818 (Rev. A - 06/20)
1000005817
19. Connect both female connections on the power cord to both open terminals on the cold
control. It does not matter which connector goes on which terminal. If the connections
do not reach, spread the wire apart more to gain length. Fig. 12
18. Put the ground screw in the ring terminal on the green ground wire on the power cord.
Tighten the screw back into the frame where the old ground wire was connected.
Tighten the screw so that the terminal will not turn. To make sure that the grounding
connection is secure, use a multi-meter and check for continuity. Place one probe on
the round connector on the plug and the other probe on the frame. Fig. 11
20. Follow the wires on the power cord that will connect to the compressor. The side of
the power cord connected to the cold control will need to be connected to the overload
connection on the compressor and the side of the cord coming from the connector
block on the cord will connect to the relay on the compressor. Fig. 13
Fig. 13
Fig. 11