Installation Manual

M1G Installation and Programming
Page 67
Home Health Care (UL 1637) Listed Installations
Requirements described under UL985 plus:
* A minimum of two (2) keypads are required with one keypad powered from “+VKP” and one keypad powered from “+VAUX”.
Commercial - Central Station (UL 1610), Police Station Connected (UL 365), Local Burglar Alarm (UL 609) Listed Installations
Requirements described under UL1023 plus:
* The Alarm Cutoff timer must be set to 00900 sec. (15 min.) or greater.
* UL Commercial Burg requires 4 hours of standby power. Limit combined continuous current draw from terminals +SAUX, +VAUX, +VKP, and
connector J16 to 450 mA max. and use one (1) 8 Ah battery.
* An acceptable Commercial enclosure must be used (see Listed Enclosures below)
* A UL LIsted Tamper Switch(s) must be installed on the enclosure and connected to a 24 hour Burg Tamper defined Zone.
* All Keypads need to be installed within the protected area (they have no tamper)
* DO NOT USE an A B Attack Cabinet for the external sounder
* A Whenever/And/Then rule should be written (using ElkRP software) to enable the Output 2 Siren to ‘chirp’ upon closing ringback.
UL Canada Listed Installations (ULC S304 and ULC S303)
Requirements described under UL1023, 1610 plus:
* Entry Delay must be set to 60 seconds or less.
* Exit Delay must be set to 120 seconds or less.
* The Alarm Cutoff timer must be set to 00900 sec. (15 min.) or greater.
*UL
Canada Commercial Burg requires 24 hours of standby power. Limit combined continuous current draw from terminals +SAUX, +VAUX,
+VKP, and connector J16 is 450 mA max. and use two (2) 8 Ah batteries in parallel.
* Zone Expanders must be in an acceptable Commercial enclosure (see Listed Enclosures below)
Appendix F - Regulatory Agency Statements (cont)
GE “Caddx” NX003-C Enclosure
with ELK-61205684 Adapter Plate
GE “Caddx” NX003-C Enclosure with M1 Control
Mounted on ELK-61205684 Adapter Plate
GE “Caddx” NX003-C Enclosure shown
with M1 Control and M1XIN Zone Expander
LISTED ENCLOSURES:
For Household Burglar or Household Fire Listed Installations one of the following enclosures must be used:
* ELK 14” Enclosure model ELK-SWB14 or ELK-UB14
* ELK 28” Enclosure model ELK-SWB28
* OnQ Legrand 14” Enclosure models 363474-01or 363474-11 utilizing the Universal Mounting plate part no. 364453. Not LISTED FOR CANADA
* OnQ Legrand 28” Enclosure models 363475-01, 363475-11, 364591-01, 364591-02 or364591-11 utilizing the Universal Mounting plate part no.
364453. Not LISTED FOR CANADA
* OnQ Legrand 42” Enclosure models 363476-01,363476-11,364592-01, 364592-02, or 364592-11 utilizing the Universal Mounting plate part no.
364453. Not LISTED FOR CANADA
For Commercial Listed Installations one of the following enclosures must be used:
* ELK-TB14 Tamper Resistant Enclosure
* GE “Caddx” NX003-C with an ELK-61205684 Mounting Adapter Plate (See diagrams below)