TEXTS - This section allows custom text messages to be constructed and formatted. These messages can be transmitted
to an LCD keypad or out one of the RS232 serial ports to a PC or some other type of equipment. A message to the keypad
could be “Happy Birthday” or “Please Pay Your Bill”, while a message going out a serial port might be a series of ASCII
characters formatted to a certain manufacturers protocol. Special options built into this menu include: automatic display of
temperature readings from Zone Temperature Sensors (ELK-M1ZTS) and from the temperature sensor built into an LCD
Keypad. The sending or receiving of text messages is controlled by the automation rules engine. NOTE: Text messages
share the same memory space as rules. The total number of text messages and rules is limited by the M1 model that
you are installing.