Installation manual
M1EZ8 Installation and Programming
Page 5
Wiring & Hookup Diagram
-
STATUS
LINE SEIZE
N.C.
N.O.
2200
Ohm
EOL
N.C.
N.O.
Zone
8
2200
Ohm
EOL
POWER
Data Bus-See Note in Manual
RED
BLACK
WHITE
GREEN
Keypad
+
See Manual
Do Not Connect
to a Phone Line!
JP1
2WIRE
SMOKE
NORMAL
ZONE 8
JP3
Lighting Interface
or M1EZ8MSI Main
Serial Port Interface ††
Aux Data Bus (J3) ††
For wireless receiver. Presently
works with GE-Caddx NX408E,
NX416E, or NX448E
Two-Way
Listen-In (J7) ††
Connects to
(M1EZ8TWI)
TELCO
Line
House
Phones
TR
T1 R1
RJ31X Jack
(ELK-RJSET)
5
4
8 1
Demark
Block
splices
Yellow
Black
Red
Green
Green Red Brown
PHONE LINE HOUSE LINE
TIP RING T1 R1
Z7NEGZ8
Compiles with FCC Part 68
Reg. Number: US:5K6AL03BELK-M1
Ringer Equivalence REN: 0.3B
Use USOC RJ-31X connector.
Complies with the limits for class B computer
devices in accordance with the specifications
of subpart J of part 15 of FCC rules.
Out 3 - Relay Programmable
General Purpose Dry Contacts
rated: 4 Amps @ 12 - 24VDC
Select PLC Mode (JP2)
Selects single or bi-directional
PLC Transmissions
Terminating Jumper (JP3)
See manual for important
information about Data Bus
Termination.
12Volt - 5Ah min.
See UL requirements
for sizes and standby
times. Test regularly
with ELK-BLT Battery
Life Tester. Replace
every 3-5 years
16V XFMR
AC
AC
A B
+12V
KP
NEG
OUTPUT 3
N/O N/CCOM
Line Seize LED is ON if Dialer
is in use (communicating)
Status LED:1 blink = Normal Operation.
2 fast blinks = Bootloader mode.
4 fast blinks = Initializing EEPROM memory.
5 fast blinks = Memory/Operation overflow.
Power LED is ON when AC is present.
Auxiliary +12VDC
Power Output
Protected by 1.25A PTC.
2200 Ohm EOL Resistors are part # ELK-ER2200
ELK-M1EZ8
J3
-
C
+
B
A
1
J7
1
2 WAY
1 WAY
-X10-
JP2
J5
18
+12VDC Switched
Smoke Power
1.1 Amp PTC protected
4-Wire Smoke Detector
2200
Ohm
EOL
To Zone Input
U.L. Listed EOL Supervision Relay
(ESL #204 or Equivalent).
(shown energized, contacts closed)
N.O. Alarm
Contacts
To Zone NEG
+VAUX +VSMK
Grey
Ring
Tip
T1 R1
Programmable Outputs (J16)
OUT 7 thru 16 are +12V switched positive voltage
outputs rated at 10mA max. Connect optional ELK-
M1RB Relay Board for 8 general purpose relays.
J16
OUT 16
OUT 15
OUT 14
OUT 13
OUT 12
OUT 11
OUT 10
OUT 9
OUT 8
OUT 7
+12V
NEG
Red
Black
White
Green
Brown
Blue
Yellow
Violet
Pink
Tan
Orange
Grey
+ ALARM -
OUTPUT 2
NEG
-
+
Connector J5 accepts either a 4 conductor modular cable for a PSC05 PLC
Lighting Interface OR an 8 conductor modular cable for a EZ8MSI Main Serial Port
Interface w/PSC05 pass through connector. (This connection not evaluated by UL)
PSC05 ††
or equiv.
PSC05 or
Equivalent
PC
Computer, OEM
component, etc.
RS-232
ELK-M1EZ8MSI
Main Serial Port Interface
J3
RS232
Serial
Cable
4 Conductor
Modular Cable
8 Conductor
Modular Cable
11
J1
From
EZ8
J2
Powerline
Interface
To J5
Connector
4
C
o
n
d
u
c
t
o
r
M
o
d
u
l
a
r
C
a
b
l
e
OR
1
BATTERY
RED BLK
Zone
7
-
+
+
-
(Sold separately)
12V
Battery
Yellow
Green
Red
Black
4 conductor modular (standard) phone
cord for PLC Lighting (not supplied).
End view
Yellow
Green
Red
Black
1
1
8 Conductor Cat5 cable from EZ8MSI Main Serial Port Interface.
End view
Brn/Wht
Wht/Brn
Grn/Wht
Wht/Blue
Blue/Wht
Wht/Grn
Org/Wht
Wht/Org
1
Wht/Org
Org/Wht
Wht/Grn
Blue/Wht
Wht/Blue
Grn/Wht
Wht/Brn
Brn/Wht
1
110806
ELK
PRODUCTS, INC.
HILDEBRAN, N.C., 28637, USA
NOTE: Refer to Appendix F in the Installation Manual
#L523 Rev. I 05/07 for the UL limitations on total
continuous 'standby' current drain from terminals
+VAUX, +12VKP, +VSMK, and J16.
N.C.
N.O.
2200
Ohm
EOL
N.C.
N.O.
Zone
6
2200
Ohm
EOL
Z5NEG
Zone
5
Z6
N.C.
N.O.
2200
Ohm
EOL
N.C.
N.O.
Zone
4
2200
Ohm
EOL
Z3NEGZ4
Zone
3
N.C.
N.O.
2200
Ohm
EOL
N.C.
N.O.
Zone
2
2200
Ohm
EOL
Z1NEG
Zone
1
Z2
11
RS232 Serial Port Cable (9 pin male
to 9 pin female) Max. length = 50 ft.
Pin 2 < to > 2
Pin 3 < to > 3
Pin 5 < to > 5
Sealed Lead Acid Battery (ELK-1250)
Note: Secondary phone line surge
suppression devices (ELK-950) are
recommended for areas prone to transient
or lightning strikes.
+
2-Wire Smoke Detector
820
Ohm
EOL
+
-
NEG
Z8
Compatibility Identifier: M10001
Maximum Operating Voltage: 13.8 VDC
Max. wire resistance should not exceed 13 Ohms.
Use 18AWG Fire approved wire. Max. wire length = 1000 feet.
Do not mix different models on same circuit as proper operation may be impaired.
Name
System Sensor
Sentrol (GE)
Model
2W-B, 2WT-B, 1151, 2100, 2100T, 2151
429AT, 521BXT, 521B
Compatibility ID
A
S09A
Max #
20
20
Base
None
None
To configure Zone 16 as a 2-wire smoke zone, set Jumper JP1 to "2 WIRE
SMOKE" and use 820 Ohm EOL resistor, part # ELK-ER820.
2-Wire Smoke Detector Compatibility
† †
16.5VAC, 45VA
ELK-TRG1640)
Do not connect to
switched outlet.
UL Listed Class 2 Transformer
For Canada use cUL Listed
Transformer - ATC Frost #FPS-4016
This unit provides Residential fire alarm service when installed according to
ANSI/NFPA 72. Transmission of the fire alarm signal to a fire alarm
headquarters or central station shall be permitted only with the approval of the
authority having jurisdiction. The burglar alarm signal shall not be transmitted
to a police emergency number, equipment is to be installed in accordance with
NFPA (985,55.1.P). Reference NFPA70 (NEC) & Canadian Electrical Code.
All circuits are current limited except for Battery leads. Refer to Appendix F.
Testing of system should be performed regularly with the primary AC power
de-energized. Control specifications are subject to change without notice.
For Installation of Residential Fire Warning Systems reference CAN/ULC-S540
Standard.
Smoke Detector covers should be kept free from dust and dirt by use of a dry
or damp (water) cloth as needed. When necessary, clean the detector interior
and/or replace the optical chamber according to instructions provided by the
Smoke Detector Manufacturer.
M1EZ8 "Board only" non-alarm current draw = 140mA ( .14 Amp )
Out 2 - Alarm Connect ONLY 1
UL Listed Bell or Siren (self-
contained). For residential Fire
the indication device shall be
Wheelock 34T-12 or equiv.
Current limited to 1 Amp.
Program Global Option 26 to
Voltage. Speakers are only
permitted for non-UL installations
and must be series parallel wired
to avoid dropping below a 4 ohm
total load.
† Not evaluated by UL †† Not for use in UL Listed Systems
††
††
††
Use 26AWG
Telco wire