Installation manual
M1EZ8 Installation and Programming
Page 33
G14: =No Out1&2r
Chg YelpToBuzzer
G15 - G25
Menu 07 - Global System Definitions (continued)
Global Sys Definitions Description of Option
Any of the Areas 2 thru 8 may be made common to Area 1. The result is: Area 1 cannot
be armed until all its common areas are armed. Once armed, Area 1 will disarm if any
common area becomes disarmed. This is good for lobbies or vestibules shared by two or
more persons. Each area must have its own keypad. NOTE: If you want Area 1 to
automatically arm when all its common areas become armed, use a Whenever/
And/Then rule from the RP software to do this.
Changes the Burglar Yelp sound on outputs 1 & 2 to a pulsing Buzzer sound. NOTE:
Out1 is designed for 8 Ohm - 20 watt min. speakers (up to 4 max) and has
adjustable volume settings. Default is No.
Options G15 thru G25 are not available (not programmable in the ELK-M1EZ8)
Allows Output 2 to be converted from a siren driver into a voltage only output. If set to
“No” the control produces alarm sounds for use with 8 Ohm speakers. If set to “Yes” the
control will produce +12 Volts for use with self-contained sirens or bells. Default is No.
Ordinarily, Outputs 1 & 2 activate immediately on alarms. However, Output 2 can be time
delayed up to 255 seconds. Using Output 1 strictly for interior sounders and Output 2 for
outside sounders, a false alarm will be heard inside first, giving the user time to disarm
before any outside sounders are activated. A “good neighbor” feature. Default is 000.
G13:_ _ _ _ _ _ _ _r
Common To Area1
G26: =No r
Out2 Voltage Out
G27:=000secOut2r
Delay Turn-On