Installation manual

M1XSP Installation Manual
Page 2
APPLICATION:
The ELK-M1XSP is a "3 in 1" product. As a lighting interface, it adapts the M1 Control to many brands of Lighting control
products which use “serial" communications. i.e.,OnQ-ALC, PCS-UPB, EDT, CENTRALITE, etc. As a thermostat
interface, it adapts the M1 Control to HVAC Communicating Thermostats from companies such as:RCS, APRILAIRE,
and HAI. As a serial port expander, it expands the RS-232 communication ports of the M1 for multiple connections
to most any type of equipment that communicates using serial ASCII commands. i.e., Personal Computers and many
types of equipment which feature an RS-232 communications connection. Jumpers on the M1XSP select the
appropriate application, connection, and protocol. Best of all, the M1XSP operates from the 4-wire (RS-485) M1 Keypad
data bus, allowing RS-232 ports to be located long distances from the control. The M1G (Gold) and M1EZ8 Cross
Platform Controls support up to 7 M1XSPs. The communications baud rate is adjustable from 300 to 38,400 baud.
The unit comes complete with cable and a black surface mountable housing.
FEATURES:
Adapts the M1 and M1EZ8 to specific Lighting control products which use "serial" communications.
Adapts the M1 and M1EZ8 to specific HVAC Communicating Thermostats from RCS, Aprilaire, and HAI
Expands the M1 and M1EZ8 RS-232 Serial Ports
Connect to and Operates from the RS485 Data Bus
Address Settings via DIP Switches
Jumper Options and LED Diagnostic indicator
On-Board EOL Bus Termination Jumper
Flash Memory for Firmware Updating
SPECIFICATIONS:
Maximum of Expandable Ports (Units): 7 with M1G or M1EZ8
Operating Voltage: 12 Volts D.C.
Current Draw: 31mA
Housing Dimensions: 4.375" x 3.0" x 1.125"
Circuit Board Dimensions: 3.5" x 2.75
Table of Contents
General Installation and Setup ..................................................................................................... 3
Updating/Replacing Firmware in the ELK-M1XSP....................................................................................4
Aprilaire 8870 Thermostat(s)......................................................................................................... 5
RCS TR16 (RS-232 Format) Thermostat(s) ................................................................................. 6
RCS TR16/TR40 (RS-485 Format) Thermostats(s)...................................................................... 7
HAI RC Series (RS-232 Format) Thermostat(s) ........................................................................... 8
Lighting Controllers with RS-232 "Serial" Interfaces ................................................................. 9
OnQ-ALC - (Individual Lighting Switches) .................................................................................. 10
UPB - (Individual Lighting Loads and Links) .............................................................................. 12
Centralite LiteJet - (Individual Lighting Loads and Scenes) ....................................................... 14
Lutron RadioRA - (Phantoms, Zones, Security Flash/Solid, Master Ctrl Buttons) ........................ 16
Insteon - (Individual Lighting Loads and Scenes) ....................................................................... 18
UPLINK "AnyNET" Cell Radio Backup ..................................................................................... 22
W800RF32 X-10 RF Receiver from WGL Associates ................................................................ 23
Data Bus E.O.L. Termination - VERY IMPORTANT! ................................................................... 24
M1XSP Compatibility, Jumper Settings and Misc. Information ................................................ 26