Installation manual

M1G Installation and Programming
Page 7
(Right Side Terminals)
OUT1
+12V (+VAUX)
NEG
16
15
14
13
12
11
10
9
8
7
NEG -
DATA B
+12V
DATA BUS
-
A
B
C
J3 J4
1 WAY
PLC
Mode
2 WAY
JP2
RS232
+
J16
J5
OUT3 LED
OUT3OUT2
+
-
+
-
+VKP
DATA B
DATA A
NEG
Not Used
R1
TIP
RING
T1
* See Auxiliary Current ratings
1 WAY (PL513/PSC04)
Select PLC Mode (JP2)
Selects single or bi-directional
PLC Transmissions
2 WAY (TW523/PSC05)
JP2
Voice/Siren
OUTPUTS
AUDIO NETWORK INTERFACE
J7
Aux Data Bus (J3) ††
For wireless receiver. Presently
works with ITI / Caddx NX408E,
NX416E, or NX448E. See
Programming Menu 14.
Audio Network Connection (J7) ††
For Two-Way Listen-in and Future Use!
J1J2
NEG
+12V
N/CCOMN/O
Compiles with FCC Part 68
Reg. Number: US:5K6AL03BELK-M1
Ringer Equivalence REN: 0.3B
Use USOC RJ-31X connector.
Complies with the limits for class B computer
devices in accordance with the specifications of
subpart J of part 15 of FCC rules.
Out 3 - Programmable General Purpose Relay
Rated at 4Amps @ 12 - 24VDC
(Dry Contacts)
Terminating Jumper (JP3): See
important information about Data
Bus Termination.
This terminal (formerly earth ground) is no longer used. Do not connect this or any neg. terminals to earth ground.
Out 1 - Voice/Siren ††
Speaker output only (Interior)
Out 2 - Connect ONLY 1 UL Listed Bell or Siren (self-contained). For residential Fire the indicating
device shall be Wheelock 34T-12 or equiv. Current limited to 1 Amp. Program Global Option 26 to Voltage.
Speaker(s) are only permitted for non-UL installations and they must be series/parallel wired to avoid
dropping below a 4 ohm total load.
Programmable Outputs (J16)
OUT 7 - 16 are +12V switched
positive general purpose
outputs rated at 50mA.
Lighting ††
Interface Conn.
RJ31X JACK (ELK-RJSET)
PC
Personal Computer
(Windows Based)
Serial Port (J4) †
for Computer/ELKRP
(This connection not
evaluated by UL)
Lighting Interface Conn. (J5) ††
Use Std. 4 conductor modular telephone
cable to connect to a powerline Interface
(PSC05, X-10 PLC or equiv.).
Do not connect to a live phone line!
(This connection not evaluated by UL)
N/C
COM
N/O
DATA BUS TERMINATION IS VERY IMPORTANT!!
Diagram shows 2 basic (4-wire) home run cables with daisy chained devices on each. Last device on each cable
MUST have a Terminating Jumper installed. Jumpers are marked JP2 on keypads, JP1 on Expanders. Control
Hardware pack has two black jumpers for this purpose. Jumpers engage a 120 Ohm resistor across data A & B lines.
NOTE: If there is only 1 data bus cable, install JP3 Jumper on the Control.
Temporary Connection "Plug-in" jacks for RS-485 Data Bus (J1 & J2)
Local connection for Data Bus Devices ie: Keypads, etc. for testing purposes only.
ELK-SP35 or equiv.
PSC05 or
equiv.
Relay Expansion Module (ELK-M1RB)
Optional module adds 8 general purpose
relays. Plugs into J16 connector.
Red
Black
White
Green
Brown
Blue
Yellow
Violet
Pink
Tan
Orange
Grey
+VAUX
NEG
OUT 16
OUT 15
OUT 14
OUT 13
OUT 12
OUT 11
OUT 10
OUT 9
OUT 8
OUT 7
+12V
NEG
Green
Grey
Red
Brown
BLACK
WHITE
GREEN
JP3
RS-485 Data Bus Max. length is 4000 ft. Total
length of 2 homeruns must not exceed that distance.
NOTE: If you want to home run more than 2 cables, run 6 or 8 conductor cable so that the data lines A & B can have a
return path to series connect back out to the next device. This is best done with a ELK-M1DBH Data Bus Hub which
accepts Cat5 or Cat6 cable with RJ45 plugs. For more information see diagram in keypad instructions.
WARNING! The RS485 Data Bus must NEVER have more that two (2) terminating jumpers installed.
RS-485 DATA BUS
DATA A
RED
Data Bus Devices e.g. Keypads, Expanders
Jumper
Terminate
these two
devices.
DO NOT Jumper
Terminate these devices.
Yellow
Green
Red
Black
Yellow
Green
Red
Black
Close up view of std. 4 conductor modular phone cord. When
viewed as shown (back to back), the pin to pin color coding
does not reverse. Cord for PLC must be similar to above.
End
view
11
Pin 2 < to > 2
Pin 3 < to > 3
Pin 5 < to > 5
Pinout for Serial Port Cable (9 pin male to 9 pin female)
Maximum recommended length = 50 ft.
Out 2 is supervised. If not used, install a 2.2K Ohm
resistor to avoid Output 2 trouble condition.
NOTE: Do Not place a Direct Short Across OUTPUT 2.
Bell (Supervised)
+
+
-
-
TELCO
LINE
HOUSE
PHONES
T
R
T1
R1
5
4
8
1
Tip
Ring
Green
Red
Yellow
Black
Demark
splices
† Not evaluated by UL †† Not for use in UL Listed Systems
Use 26AWG telco wire
A UL Listed Supplementary Power Supply may be required to meet the minimum standby
power supply requirements. Refer to the Chapter containing Regulatory Agency Statements.
Min. wire gauge: 24 AWG
18 to 22 AWG is best for
long distances.