Installation manual

M1G Installation and Programming
Page 45
SR14: T=00 R=00 r
Phone Line Fault
SR15: T=00 R=00 r
Output 2 Trouble
SR13: 00= Up/ r
Download End
Log 80% Full reports whenever the Event Log becomes 80% full. Range is 00 to FF.
Default is 00 (no report). The Elk-RP is required to download the log and/or clear it.
T (Trouble) is code reported if battery test drops below 11.2 Volts. R (Restore) is code
reported once battery test passes at 11.5 Volts or higher. Range is 00 to FF. Default is
00 (no report).
THIS PROGRAMMING LOCATION IS NO LONGER USED
Code reported upon completion of a Up/Download session. This can be used as a
verification that the control was accessed. Range is 00 to FF. Default is 00 (no report).
T (Trouble) is code reported upon detection of Voltage/Current loss on the telephone line.
R (Restore) is code reported immediately upon restoral of the telephone line. Range is 00
to FF. Default is 00 (no report).
To avoid nuisance reports caused by brief phone outages caused by telephone linemen or
central office repairs, there is a 3 minute (default) time delay before telephone line fault is
annunciated and reported. The delay time is programmed from 01 to 31 seconds but
ONLY by use of the ElkRP Programming Software. [A delay of 01 is the same as 00 or
instant]
T (Trouble) is code reported upon an open circuit occuring on Output 2. R (Restore) is
code reported upon restoral of the connection. Range is 00 to FF. Default is 00 (no
report).
Menu 12 - Sys Report Code Options & Codes (continued)
Sys Rpt Code Options Description of Option
SR11: T=00 R=00 r
Low Battery
SR12: T=00 r
Memory Error
System RCs CID SIA
AC Fail 301 A T
AC Restore 301 A R
Automatic Test 602 R P
Aux Over Current 312 Y P
Aux Over Current Restore 312 Y Q
Expansion Module Trouble 333 E T
Expansion Module Restore 333 E R
Local Programming Begin 627 L B
Local Programming End 628 L X
System RCs CID SIA
Log 80% Full 623 J L
Low Backup Battery 302 Y T
Low Battery Restore 302 Y R
Memory Error 304 Y F
Remote Programming End 412 R S
Telephone Line Fault 351 L T
Telephone Line Restore 351 L R
Output 2 Trouble 322 Y A
Output 2 Restore 322 Y H
Based on the event, the CID (Contact ID) or SIA Codes for System Reporting Codes will be:
NOTE: On CID reporting the 3 digit code is preceded by a “1” for new events
or a “3” for restore (previous reported) events.
SR10: 00= Logr
80% Full
NOTE: UL requires that a Technician be On-Site when doing Remote Programming.