SR01: 015=AC Fail
Rpt Delay - Minr
SR02: T=00 R=00 r
AC Fail Codes
SR03: 00 = Autor
Test Code
Menu 12 - Sys Report Code Options & Codes
12-Sys Rpt Code r
Options & Codes
Sys Rpt Code Options Description of Option
Reporting of AC Fail may be delayed from 001 to 255 minutes. Default is 15 minutes.
Setting this location to 255 results in no AC failure at the keypad or reporting by the dialer.
T (Trouble) code is code reported upon AC failure, after any AC Fail Rpt delay time. R
(Restore) is code reported immediately upon restoral of the AC power. Range is 00 to FF.
Default is 00 (no report).
Auto Test code is used to verify that the telephone line and internal communications
circuitry is functioning properly. Range is 00 to FF. Default is 00 (no report).
Auto Test Hr:Min may be set to occur at any specific hour and minute, using military time
format. IE: 7:30 is AM, 19:30 is 7:30pm. Default is 00:00 (Midnight)
Can be used to skip Auto Test for a number of days, (000 to 255). A value of 000 or 001 is
one in the same, resulting in the test code being reported daily at the Auto Test time.
T (Trouble) is code reported when auxiliary power overload is detected. R (Restore) is
code reported when the overload ceases. Range is 00 to FF. Default is 00 (no report).
T (Trouble) is code reported when an enrolled data bus module fails to respond or is
missing. R (Restore) is code reported when module is restored. Range is 00 to FF.
Default is 00 (no report).
Used to report when the Installer Level of Programming has been entered. Range is 00 to
FF. Default is 00 (no report).
Used to reporting when Installer Programming has ended. Report not sent until the * key
is pressed 3 time, signifying final program end. If the * key sequence is not pressed, the
report will occur automatically at Midnight. Range is 00 to FF. Default is 00 (no report).
SR04: =00:00 r
Auto Test Hr:Min
SR05: 000=Days r
Between AutoTest
SR06: T=00 R=00 r
Aux Overcurrent
SR07: T=00 R=00 r
Exp Module Tbl
SR08: 00=Instalr
Program Begin
SR09: 00=Instalr
Program End
Press RIGHT arrow key to select this menu. Press UP or DOWN arrow keys to select
another menu. The ELK key backs up one menu level. To exit press the * or Exit key.
System Report Codes and Options are global to the entire system such as Low Battery, AC Fail, etc. Using the up/down
arrow keys, select the appropriate option, then press the right arrow key to begin programming that option.
NOTE: Enter a two digit value to enable a report code, enter 00 to disable. With SIA or Contact ID format, the two digit
value can be 01 as the control automatically inserts the correct code according to the SIA or Contact ID protocol. For
4+2 pulse format, enter 01 to FF. For A thru F HEX characters press the RIGHT arrow key to position the cursor under
the desired digit, then press the UP arrow (shift) key once. Presses of the 2 key produces the following: 2, A, B, C.
Presses of the 3 key produces the following: 3, D, E, F. Press the RIGHT arrow key to cancel shift and move to the
next character. See Appendix for a summary of the SIA and Contact ID codes.