Installation manual

M1G Installation and Programming
Page 4
OUT3 On LED
J-16 Programmable Outputs
See Note 1
& Note 2
PLC ††
Lighting
Interface
Conn.
J4
1 WAY
(PL513/PSC04)
Select PLC Mode
2 WAY
(TW523/PSC05)
JP2
RS232 CONN.
J5
Bell (Supervised)
Voice/Siren † †
Dry Contact Relay
rated 4A @
12 - 24VDC
See Note 2
OUT 1 OUT 3
N/C
COM
N/O
OUT 2
RED
BLACK
WHITE
GREEN
+VAUX
+12VDC Auxiliary
Power (3)
1.25 Amp PTC
protected
Grey
Brown
Red
Green
TELCO
LINE
HOUSE
PHONES
Z1
NEG
Z2
Z3
NEG
Z5
NEG
Z7
Z6
Z4
NEG
Z8
Z9
NEG
Z10
Z11
NEG
Z13
NEG
Z15
Z14
Z12
NEG
Z16
+SAUX
NEG
+VAUX
NEG
+VAUX
NEG
+VAUX
NEG
AC
16.5 V
AC
+VKP
DATA B
DATA A
NEG
OUT 16
OUT 15
OUT 14
OUT 13
OUT 12
OUT 11
OUT 10
OUT 9
OUT 8
OUT 7
+12V
NEG
T1
R1
RING
TIP
Serial Port ††
for Computer/ELKRP
See Manual
J3
B
A
-
C
+
Audio Network Interface ††
1
Keypad &
Data Bus
J2 J1
16 Zones expandable to 208
Do Not
Connect to
a Phone
Line!
Not Used -See Note 3
BATTERY
ON
SW1
+
-
12V Battery
7 to 18 Ah
Keypad
Control specifications subject to change without
notice. All circuits are power limited except for
Battery leads.
Complies with FCC Part 68:
Reg. # US: 5K6AL03BELK-M1 REN: 0.3B
Use Standard Jack: USOC RJ-31X.
Serial Number located below on base.
Complies with part 15 of FCC rules.
This Class B digital apparatus complies with
Canadian ICES-003
See Note 2
+SAUX
+12VDC Switched
Smoke Power
1.1 Amp PTC protected
NEG
DATA B
+12V
JP3
Jumper to start with
no AC - See Note 4.
Power
Status
Reverse
Bat Leads
UL Listed Transformer,
Class 2, 16.5VAC, 45VA
Do not connect to a
switched outlet.
ELK-TRG1640
NORMAL
ZONE 16
JP1
SMOKE
2WIRE
TELCO SEIZED
DIALER ACTIVE
1
N.C.
N.O.
ZONE
2200
Ohm
EOL
2
N.C.
N.O.
ZONE
2200
Ohm
EOL
3
N.C.
N.O.
ZONE
2200
Ohm
EOL
4
N.C.
N.O.
ZONE
2200
Ohm
EOL
5
N.C.
N.O.
ZONE
2200
Ohm
EOL
6
N.C.
N.O.
ZONE
2200
Ohm
EOL
7
N.C.
N.O.
ZONE
2200
Ohm
EOL
8
N.C.
N.O.
ZONE
2200
Ohm
EOL
9
N.C.
N.O.
ZONE
2200
Ohm
EOL
10
N.C.
N.O.
ZONE
2200
Ohm
EOL
11
N.C.
N.O.
ZONE
2200
Ohm
EOL
12
N.C.
N.O.
ZONE
2200
Ohm
EOL
13
N.C.
N.O.
ZONE
2200
Ohm
EOL
14
N.C.
N.O.
ZONE
2200
Ohm
EOL
15
N.C.
N.O.
ZONE
2200
Ohm
EOL
16
N.C.
N.O.
ZONE
2200
Ohm
EOL
2-Wire Smoke Detector - Zone 16 ONLY
4-Wire Smoke Detector - Any Zone
U.L. Listed EOL Supervision Relay, ESL #204A
or equiv. Use 2,200 Ohm EOL resistor, part #
ELK-ER2200. Set JP1 to 'Normal'.
DATA A
+
-
+
-
See Note 2
Data Bus Terminating Resistor
See Note 1.
Data Bus
See Note 1
J7
1.25 Amp PTC
protected
ELK
PRODUCTS, INC.
HILDEBRAN, N.C., 28637, USA
1
1
Cross Platform Control
PSC05 ††
or
Equivalent
ELK-M1
StripStrip Wires to 1/4" Length
+
820
Ohm
EOL
-
NEG
Z16
2. OUT 1 †† for speaker(s) ONLY (4 to 8 Ohms).
If connecting more than 2, use series/parallel
wiring to avoid going below a 4 ohm total load.
OUT 2 Connect ONLY 1 UL Listed Bell or
Siren (self-contained). Current limited to 1 Amp.
Program Global Option 26 to Voltage. This
output supervised. Speaker(s) only permitted
for non-UL installations. Series/parallel wire to
avoid dropping below a 4 ohm total load.
OUT 3 NO/NC dry contact relay rated 4A.
OUT 7 through 16 are +12V switched positive
voltage outputs rated at 50mA max.
3. This terminal (formerly earth gnd) not used.
Do not connect any neg terminals to ground.
4. If AC fails, control will shut down if battery
drops below 10.2 Volts. To start the control with a
good battery and no AC, short the silver pads
momentarily. Replace Battery every 3-5 years.
Test regularly with ELK-BLT Battery Life Tester.
O - I - B A +
TM
† Not Evaluated by UL
†† Not for use in UL Listed Systems
HA008E
2200
Ohm
EOL
To Zone Input
N.O. Alarm
Contacts
+
-
+
-
+SAUX
To Zone NEG
NEG
Aux Data Bus ††
for wireless receiver
i.e. GE-Caddx
NX408E, NX416E,
or NX448E
See Manual
Notes
1. Refer to Appendix F located in the Installation
Manual #L520 Rev. J for UL limitations on total
continuous 'standby' current drain from terminals
+SAUX, +VAUX, +VKP, and J16.
To configure Zone 16 as a 2-wire smoke zone,
set Jumper JP1 to '2WIRE SMOKE' and use 820
Ohm EOL resistor, part # ELK-ER820
Use Only Compatible Detectors
Control Compatibility Identifier: M10001
Refer to the Wiring & Hookup Diagram in the
Installation Manual # L520 Rev. J for the 2-Wire
Smoke Detector Compatibility chart.
TEST SYSTEM WEEKLY