Installation manual

M1G Installation and Programming
Page 35
G14: =No Out1&2r
Chg YelpToBuzzer
G15:=1 Out1Startr
Alarm Volum-Tstr
G16:=7 Out1 Maxr
Siren Volum-Tstr
G17: =5 Out1 Maxr
VoiceAlmVol-Tstr
G18: =2 Out1 Nonr
AlmVoiceVol-Tstr
Menu 07 - Global System Definitions (continued)
Global Sys Definitions Description of Option
Any of the Areas 2 thru 8 may be made common to Area 1. The result is: Area 1 cannot
be armed until all its common areas are armed. Once armed, Area 1 will disarm if any
common area becomes disarmed. This is good for lobbies or vestibules shared by two or
more persons. Each area must have its own keypad. NOTE: If you want Area 1 to
automatically arm when all its common areas become armed, use a Whenever/
And/Then rule from the RP software to do this.
Changes the Burglar Yelp sound on outputs 1 & 2 to a pulsing Buzzer sound. NOTE:
Out1 is designed for 8 Ohm - 20 watt min. speakers (up to 4 max) and has
adjustable volume settings. Default is No.
Options G15 thru G18 set the start and final volume levels for alarms and non alarms.
G15 sets the initial siren/bell volume of Output 1 upon initial alarm activation. The range of
settings is selectable from 0 to 7 (0 = lowest, 7 = loudest).
Sets the maximum siren/bell volume of Output 1. The sound starts at the initial setting
and increases (volume step) every 10 seconds until the max. is reached. Volume
stepping reduces noise and confusion with user caused false alarms. Default is 7.
Sets the maximum volume of Output 1 for Voice alarm messages. Just as in G16, with a
low initial setting, the voice alarm message starts low and automatically increases
(volume stepping) over a period of time until the max. is reached. Default is 5.
Sets the maximum volume of Output 1 for Voice non-alarm messages. Non-alarm
messages consist of system status, zone status, and various operating helpful hints that
are produced for the user during non-alarm conditions. Default is 2.
Selects whether or not voice messages are to be spoken through Output 1. Selecting
‘Yes” completely eliminates all spoken voice messages from Output 1. Selecting “No”
allows voices to be spoken based upon the settings of G20 through G25. Default is No.
Selects whether System “non-alarm” messages will be spoken through Output 1. System
messages include: “System is Armed”, “System is Disarmed”, etc. Default is Yes.
Selects whether Alarm messages will be spoken through Output 1.
Selects whether Zone status messages will be spoken through Output 1.
Selects whether System Trouble messages will be spoken through Output 1.
Selects whether Zone Trouble messages will be spoken through Output 1.
Selects whether Chime Event messages will be spoken through Output 1.
G19:=No Out1 r
SuppressAllVoice
G20:=Yes Out1 r
SaySystmMessages
G21:=Yes Out1 r
Say Alarms
G22:=Yes Out1 r
Say Zone Status
G23:=Yes Out1 r
SaySystemTrouble
G24:=Yes Out1 r
Say Zone Trouble
G25:=Yes Out1 r
Say Chime
G13:_ _ _ _ _ _ _ _r
Common To Area1